Initial results from a PET planar small animal imaging system

被引:47
作者
Siegel, S
Vaquero, JJ
Aloj, L
Seidel, J
Jagoda, E
Gandler, WR
Eckelman, WC
Green, MV
机构
[1] NIH, Dept Nucl Med, Bethesda, MD 20892 USA
[2] NIH, PET Dept, Bethesda, MD 20892 USA
[3] NIH, Ctr Informat Technol, Bethesda, MD 20892 USA
关键词
D O I
10.1109/23.775581
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A pair of stationary, opposed scintillation detectors in time coincidence is being used to create planar projection or tomographic images of small animals injected with positron-emitting radiotracers. The detectors are comprised of arrays of individual crystals of bismuth germanate coupled to position-sensitive photomultiplier tubes. The system uses FERA (LeCroy Research Systems) charge-sensitive ADCs and a low cost digital I/O board as a FERA bus-to-host bridge. In projection mode, the animal is placed within the 55 mm x 45 mm useful field-of-view of the detectors and images are formed from coincidence lines that fall close to the normals of both detectors. In tomographic mode, the animal is placed on a rotation stage between the detectors and rotated around a vertical axis to acquire all possible lines-of-response. Tomographic images are then reconstructed from those lines falling within a user-specified angle of each detector normal. In mice, the system is capable of high-speed, whole-body dynamic projection imaging, and whole body tomographic imaging of slowly varying tracer distributions. An ECG gating capability is also available for evaluating cardiac function. This system is currently being used to study tracer transport in normal and genetically engineered mice.
引用
收藏
页码:571 / 575
页数:5
相关论文
共 19 条
[1]  
CAPECCHI MR, 1994, SCI AM, V270, P34
[2]  
Carpenter EM, 1997, DEVELOPMENT, V124, P4505
[3]   Investigation of LSO crystals for high spatial resolution positron emission tomography [J].
Casey, ME ;
Eriksson, L ;
Schmand, M ;
Andreaco, MS ;
Paulus, M ;
Dahlbom, M ;
Nutt, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1109-1113
[4]   MicroPET: A high resolution PET scanner for imaging small animals [J].
Cherry, SR ;
Shao, Y ;
Silverman, RW ;
Meadors, K ;
Siegel, S ;
Chatziioannou, A ;
Young, JW ;
Jones, WF ;
Moyers, JC ;
Newport, D ;
Boutefnouchet, A ;
Farquhar, TH ;
Andreaco, M ;
Paulus, MJ ;
Binkley, DM ;
Nutt, R ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1161-1166
[5]   Cleft palate in mice with a targeted mutation in the gamma-aminobutyric acid-producing enzyme glutamic acid decarboxylase 67 [J].
Condie, BG ;
Bain, G ;
Gottlieb, DI ;
Capecchi, MR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (21) :11451-11455
[6]   EVALUATION OF CERIUM-DOPED LUTETIUM OXYORTHOSILICATE (LSO) SCINTILLATION CRYSTAL FOR PET [J].
DAGHIGHIAN, F ;
SHENDEROV, P ;
PENTLOW, KS ;
GRAHAM, MC ;
ESHAGHIAN, B ;
MELCHER, CL ;
SCHWEITZER, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1045-1047
[7]   Retinopathy induced in mice by targeted disruption of the rhodopsin gene [J].
Humphries, MM ;
Rancourt, D ;
Farrar, GJ ;
Kenna, P ;
Hazel, M ;
Bush, RA ;
Sieving, PA ;
Sheils, DM ;
McNally, N ;
Creighton, P ;
Erven, A ;
Boros, A ;
Gulya, K ;
Capecchi, MR ;
Humphries, P .
NATURE GENETICS, 1997, 15 (02) :216-219
[8]  
*IEEE, 1982, CAMAC INSTR INT STAN
[9]   Evaluation of 3D reconstruction algorithms for a small animal PET camera [J].
Johnson, CA ;
Seidel, J ;
Carson, RE ;
Gandler, WR ;
Sofer, A ;
Green, MV ;
DaubeWitherspoon, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1303-1308
[10]   FOLATE RECEPTOR IMAGING WITH I-125 LABELED FOLIC-ACID WITH A WHOLE-BODY SMALL ANIMAL IMAGING DEVICE BUILT WITH PLASTIC SCINTILLATING OPTICAL FIBERS [J].
KULKARNI, PV ;
ANTICH, PP ;
CONSTANTINESCU, A ;
PRIOR, J ;
NGUYEN, T ;
FERNANDO, J ;
ANDERSON, JA ;
WEITMAN, SD ;
KAMEN, BA ;
PARKEY, RW ;
CHANEY, RC ;
FENYVES, EJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4) :800-803