Discrepancies between soft x-ray emissivity contours and magnetic flux surfaces in Alcator C-Mod

被引:13
作者
Borras, MC
Granetz, RS
机构
[1] Plasma Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139
关键词
D O I
10.1088/0741-3335/38/3/005
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The soft x-ray diagnostic system of Alcator C-Mod, equipped with 152 detectors distributed in four arrays, is used to obtain iso-emissivity surfaces. These surfaces have been characterized by giving their elongation and relative shift from the centre of the tokamak as functions of plasma radius. Flux surfaces, provided by magnetic diagnostics, have also been described with elongation and shift. Results from the comparison of the two sets of geometric parameters obtained from magnetic and x-ray diagnostics are presented. We find that, whereas the shifts obtained from these two diagnostic methods are always in good agreement, the corresponding elongation curves show different patterns. An agreement between elongations better than 2% is only found in a range of about 2 cm in minor radius. On the other hand, the elongations can differ by 10% towards the plasma edge and the plasma centre. Error bars for the x-ray diagnostic are obtained by propagating the effect of +/- 1% random errors at the detector signals, and can amount to +/- 1-2% of the estimated values near the edge and the centre of the plasma. The estimated uncertainties in the determination of elongation from magnetic flux surfaces are of the order of 4%. A series of tests and simulations performed to verify the accuracy of the x-ray diagnostic system is presented. The discrepancies found could imply the existence of asymmetries in impurity concentration.
引用
收藏
页码:289 / 300
页数:12
相关论文
共 19 条
  • [1] BORRAS MC, 1994, 36 ANN M APS DIV PLA
  • [2] DETERMINATION OF CURRENT DISTRIBUTION IN JET FROM SOFT-X-RAY MEASUREMENTS
    CHRISTIANSEN, JP
    CALLEN, JD
    ELLIS, JJ
    GRANETZ, RS
    [J]. NUCLEAR FUSION, 1989, 29 (05) : 703 - 711
  • [3] SOFT-X-RAY TOMOGRAPHY DIAGNOSTIC AT THE RTP TOKAMAK
    DACRUZ, DF
    DONNE, AHJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (07) : 2295 - 2305
  • [4] RAPID COLLAPSE OF A PLASMA SAWTOOTH OSCILLATION IN THE JET TOKAMAK
    EDWARDS, AW
    CAMPBELL, DJ
    ENGELHARDT, WW
    FAHRBACH, HU
    GILL, RD
    GRANETZ, RS
    TSUJI, S
    TUBBING, BJD
    WELLER, A
    WESSON, J
    ZASCHE, D
    [J]. PHYSICAL REVIEW LETTERS, 1986, 57 (02) : 210 - 213
  • [5] FONCK RJ, 1988, PPPL2518
  • [6] FONCK RJ, 1986, PPPL2374
  • [7] SOFT-X-RAY TOMOGRAPHY ON TOKAMAKS USING FLUX COORDINATES
    FUCHS, G
    MIURA, Y
    MORI, M
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 1994, 36 (02) : 307 - 316
  • [8] GILL RD, 1995, COMMUNICATION
  • [9] Granetz R. S., 1991, International School of Plasma Physics `Piero Caldirola' Diagnostics for Contemporary Fusion Experiments. Proceedings of the Workshop, P425
  • [10] X-RAY TOMOGRAPHY ON JET
    GRANETZ, RS
    SMEULDERS, P