Piezoelectric flow injection analysis biosensor for the detection of Salmonella typhimurium

被引:23
作者
Babacan, S
Pivarnik, P
Letcher, S
Rand, A
机构
[1] Dept Food Sci & Nutr, W Kingston, RI 02892 USA
[2] Univ Rhode Isl, Sensor & Surface Technol Partnership, Fiber Opt & Biosensor Res Grp, Kingston, RI 02881 USA
[3] Univ Rhode Isl, Dept Phys, Kingston, RI 02881 USA
关键词
piezoelectric; biosensor; Salmonella; protein A; flow injection analysis;
D O I
10.1111/j.1365-2621.2002.tb11403.x
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Piezoelectric biosensors have the potential to provide direct detection of food contaminants, such as pathogens. In this study, Protein A antibody immobilization was used for the activation of the piezoelectric biosensor to detect Salmonella typhimurium. The overall system consisted of a new design for a flow cell and flow injection analysis system. The How cell made possible a baseline stability of +/-1 Hz out of 5 MHz for hours. The sensor had responses of 5 to 65 Hz in 30 min with R-2 = 0.95 for S. typhimurium concentrations of 10(7) to 10(9) CFU/ml under continuous flow, and 3 to 75 Hz in 40 min with R-2 = 0.96 for S. typhimurium concentrations of 106 to 1010 CFU/ml under stop flow. Cross-reactivity tests were performed with nonpathogenic Escherichia coli, Escherichia coli O157.H7, Listeria monocytogenes, and Vibrio parahaemolyticus and showed less than 10% response.
引用
收藏
页码:314 / 320
页数:7
相关论文
共 20 条
[1]   Evaluation of antibody immobilization methods for piezoelectric biosensor application [J].
Babacan, S ;
Pivarnik, P ;
Letcher, S ;
Rand, AG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :615-621
[2]  
BANWART GJ, 1989, BASIC FOOD MICROBIOL, P248
[3]   QUARTZ-CRYSTAL MICROBALANCE DETECTION OF VIBRIO-CHOLERAE O139 SEROTYPE [J].
CARTER, RM ;
MEKALANOS, JJ ;
JACOBS, MB ;
LUBRANO, GJ ;
GUILBAULT, GG .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 187 (01) :121-125
[4]   RAPID DETECTION OF SALMONELLA IN FOODS USING EF-18 AGAR IN CONJUNCTION WITH THE HYDROPHOBIC GRID MEMBRANE-FILTER [J].
ENTIS, P ;
BOLESZCZUK, P .
JOURNAL OF FOOD PROTECTION, 1991, 54 (12) :930-934
[5]  
*FDA, 1992, BACT AN MAN
[6]  
JACOBS MB, 1995, AM LAB, V27, P26
[7]  
KOOYMAN RPH, 1997, HDB BIOSENSOR ELECT, P186
[8]   A QUARTZ CRYSTAL BIOSENSOR FOR MEASUREMENT IN LIQUIDS [J].
KOSSLINGER, C ;
DROST, S ;
ABERL, F ;
WOLF, H ;
KOCH, S ;
WOIAS, P .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (06) :397-404
[9]   OPERATION OF AN ULTRASENSITIVE 30-MHZ QUARTZ-CRYSTAL MICROBALANCE IN LIQUIDS [J].
LIN, ZX ;
YIP, CM ;
JOSEPH, IS ;
WARD, MD .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1546-1551
[10]   Food-related illness and death in the United States [J].
Mead, PS ;
Slutsker, L ;
Dietz, V ;
McCaig, LF ;
Bresee, JS ;
Shapiro, C ;
Griffin, PM ;
Tauxe, RV .
EMERGING INFECTIOUS DISEASES, 1999, 5 (05) :607-625