The reproducibility of endometrial volume acquisition and measurement with the VOCAL-imaging program

被引:97
作者
Raine-Fenning, N [1 ]
Campbell, B [1 ]
Collier, J [1 ]
Brincat, M [1 ]
Johnson, I [1 ]
机构
[1] Queens Med Ctr, Sch Human Dev, NURTURE, ACAD Div Reprod Med, Nottingham, England
关键词
endometrial volume; intraobserver; measurement technique; repeatability; reproducibility; three-dimensional ultrasound; VOCAL;
D O I
10.1046/j.0960-7692.2001.00608.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To determine the intraobserver reproducibility of volume acquisition and repeatability of endometrial volume measurements using the VOCAL(TM)-imaging program (Virtual Organ Computer-aided AnaLysis). Methods Ten three-dimensional (3D) ultrasound datasets of the same endometrium were obtained from one patient during one scan session. For every 3D dataset, the endometrial volume was calculated by four different measurement techniques; three rotational methods and one conventional method. A single observer acquired each dataset and conducted all measurements. For the rotational technique, the manual mode was used to trace the myometrial-endometrial border through three different predefined rotations of 30degrees, 15degrees and 9degrees. Endometrial volume was also measured in a conventional manner by scrolling through one of the multiplanar images and outlining the contour in another. Ten consecutive measurements were taken for each of the four measurement techniques so that 40 endometrial volume readings were obtained for each of the 10 3D-ultrasound datasets. Results Endometrial volume measurements were more reproducible with the rotational technique. Rotational methods employing a rotation step of less than 30degrees were associated with coefficients of variation below 1% and intraclass correlation coefficients above 0.94. Within each of the 10 different scans, the homogeneity of the variance of measurements was significantly different according to the method measurement (P = 0.022 to < 0.001). Post-hoc tests revealed that both the conventional and 30degrees rotational methods resulted in a significantly smaller mean endometrial volume than both the 15degrees and the 9degrees rotational methods. Conclusions Endometrial volume acquisition is reproducible and endometrial volume measurements are repeatable but they depend upon the technique of volume calculation in so much as rotational methods employing a rotation step of less than 30degrees are associated with a significantly smaller variance in measurements anti a significantly greater mean endometrial volume.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 30 条
[1]   TRANSVAGINAL ULTRASONOGRAPHY FOR IDENTIFYING ENDOMETRIAL PATHOLOGY IN POSTMENOPAUSAL WOMEN [J].
BAKOS, O ;
SMITH, P ;
HEIMER, G .
MATURITAS, 1994, 20 (2-3) :181-189
[2]   The diagnostic accuracy of ultrasound scan in predicting endometrial hyperplasia and cancer in postmenopausal bleeding [J].
Bakour, SH ;
Dwarakanath, LS ;
Khan, KS ;
Newton, JR ;
Gupta, JK .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1999, 78 (05) :447-451
[3]   Ultrasound in gynecology: Endometrium [J].
Bourne, T ;
Hamberger, L ;
Hahlin, M ;
Granberg, S .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1997, 56 (02) :115-127
[4]   The role of transvaginal ultrasound in the investigation of women with post-menopausal bleeding [J].
Briley, M ;
Lindsell, DRM .
CLINICAL RADIOLOGY, 1998, 53 (07) :502-505
[5]  
CHECK JH, 1993, FERTIL STERIL, V59, P72
[6]   ENDOMETRIAL ASSESSMENT BY TRANSVAGINAL SONOGRAPHY AND HISTOLOGICAL-FINDINGS AFTER D-AND-C IN WOMEN WITH POSTMENOPAUSAL BLEEDING [J].
CONOSCENTI, G ;
MEIR, YJ ;
FISCHERTAMARO, L ;
MAIERON, A ;
NATALE, R ;
DOTTAVIO, G ;
RUSTICO, M ;
MANDRUZZATO, G .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 6 (02) :108-115
[7]   ENDOMETRIAL PATTERN AND THICKNESS ASSOCIATED WITH PREGNANCY OUTCOME AFTER ASSISTED REPRODUCTION TECHNOLOGIES [J].
DICKEY, RP ;
OLAR, TT ;
CUROLE, DN ;
TAYLOR, SN ;
RYE, PH .
HUMAN REPRODUCTION, 1992, 7 (03) :418-421
[8]   The accuracy of transvaginal ultrasonography in the diagnosis of endometrial abnormalities [J].
Dijkhuizen, FPHLJ ;
Brolmann, HAM ;
Potters, AE ;
Bongers, MY ;
Heintz, APM .
OBSTETRICS AND GYNECOLOGY, 1996, 87 (03) :345-349
[9]   The reliability and validity of three dimensional ultrasound volumetric measurements using an in vitro balloon and in vivo uterine model [J].
Farrell, T ;
Leslie, JR ;
Chien, PFW ;
Agustsson, P .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2001, 108 (06) :573-582
[10]   The role of ultrasonography in the evaluation of endometrial receptivity following assisted reproductive treatments: A critical review [J].
Friedler, S ;
Schenker, JG ;
Herman, A ;
Lewin, A .
HUMAN REPRODUCTION UPDATE, 1996, 2 (04) :323-335