Poly(vinyl chloride)-based macrocyclic membrane sensors for magnesium

被引:15
作者
Baniwal, S [1 ]
Chandra, S [1 ]
Panwar, A [1 ]
Singh, AK [1 ]
机构
[1] Univ Roorkee, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
ion sensor; macrocycle; membrane sensor; Mg-selective electrodes;
D O I
10.1016/S0039-9140(99)00156-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly(vinyl chloride)-based membranes of macrocycles 4,11-dimethyl-2,4,9,11-tetraethyl-1,5,8,12-tetraaza cyclotetradeca-1,8-diene (I) and 4,11-dioxa-2,9-dimethyl- 1,5,8,12-tetraaza cyclotetradeca-1,8-diene (II) with sodium tetraphenyl berate (STB) as an anion excluder and dibutyl phthalate (DBP), dioctyl phthalate (DOP), dibutylbutyl phosphonate (DBBP) and 1-chloronaphthalene (CN) as plasticizing solvent mediators were prepared and investigated as magnesium selective electrodes. The best performance was observed having the composition (II)-PVC-STB-DBP in the ratio 2:10:1:7, which works well over a wide concentration range (1.9 x 10(-6) to 1.0 x 10(-1) M) with a Nernstian slope of 29 mV per decade of activity between pH 2.5 and 6.5. These electrodes have been found to be chemically inert showing a fast response time of 15 s and were used over a period of 3 months with good reproducibility (S = +/- 0.2 mV). The selectivity coefficient values for mono-, di- and trivalent cations indicate excellent selectivity for Mg2+ over a large number of cations. The electrodes have also been used successfully in partially non-aqueous medium and as an indicator electrode in the potentiometric titration of Mg2+ with EDTA. Anions such as Cl- and SO42- do not interfere in the working of the electrode. The practical utility of the membrane sensor has also been observed in solutions contaminated with detergents (cetyltrimethyl ammonium bromide and sodium dodecyl sulphate). Above all, the membrane sensor has been very successfully used to analyse some babyfood products and soft drinks for the determination of Mg2+. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:499 / 508
页数:10
相关论文
共 17 条
[1]  
ALTURA BM, 1996, SCAND J CLIN LAB INV, V56, P251
[2]  
AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
[3]   DETERMINATION AND APPLICATION OF ION-SELECTIVE ELECTRODE MODEL PARAMETERS USING FLOW-INJECTION AND SIMPLEX OPTIMIZATION [J].
DEVITERI, FJS ;
DIAMOND, D .
ANALYST, 1994, 119 (05) :749-758
[4]  
Jacob M.B., 1951, CHEM ANAL FOODS FOOD, P182
[5]  
MAHESHWARI A, 1987, THESIS U ROORKEE
[6]   EVALUATION OF THE OPTIMUM COMPOSITION OF NEUTRAL-CARRIER MEMBRANE ELECTRODES WITH INCORPORATED CATION-EXCHANGER SITES [J].
MEIER, PC ;
MORF, WE ;
LAUBLI, M ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1984, 156 (JAN) :1-8
[7]  
Morf W.E., 1981, The principles of ion-selective electrodes and of membrane transport. M. W.E, V2
[8]  
MORF WE, 1974, ANAL LETT, V7, P9
[9]  
MORF WE, 1974, CHIMIA, V28, P65
[10]   INFLUENCE OF STRUCTURAL-CHANGES ON THE ION SELECTIVITIES OF MAGNESIUM IONOPHORES BASED ON MALONIC-ACID DIAMIDES [J].
ODONNELL, J ;
RUSTERHOLZ, B ;
AEBERSOLD, B ;
RUEGG, D ;
SIMON, W ;
PRETSCH, E .
MIKROCHIMICA ACTA, 1994, 113 (1-2) :45-52