Quality assurance of imaging techniques used in the clinical management of osteoporosis

被引:10
作者
Guglielmi, G. [1 ,2 ]
Damilakis, J. [3 ,4 ]
Solomou, G. [3 ,4 ]
Bazzocchi, A. [5 ,6 ]
机构
[1] Univ Foggia, Dept Radiol, I-71100 Foggia, Italy
[2] Sci Inst Casa Sollievo Sofferenza Hosp, Dept Radiol, I-71013 San Giovanni Rotondo, FG, Italy
[3] Univ Crete, Dept Med Phys, Fac Med, Iraklion 71003, Crete, Greece
[4] Univ Hosp Heraklion, Dept Med Phys, Iraklion 71110, Crete, Greece
[5] Univ Bologna, Malpighi Hosp, Clin Dept Radiol & Histocytopathol Sci, Imaging Div, I-40138 Bologna, Italy
[6] Rizzoli Orthopaed Inst, I-40136 Bologna, Italy
来源
RADIOLOGIA MEDICA | 2012年 / 117卷 / 08期
关键词
Osteoporosis; Bone densitometry; DXA; QCT; QUS; Bone structure; X-RAY ABSORPTIOMETRY; COMPUTED-TOMOGRAPHY; CROSS-CALIBRATION; DOSE MEASUREMENTS; BONE; DXA; DIAGNOSIS; FRACTURE; STANDARDIZATION; ULTRASOUND;
D O I
10.1007/s11547-012-0881-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Recent advances in the densitometric and imaging techniques involved in the management of osteoporosis are associated with increasing accuracy and precision as well as with higher exposure to ionising radiation. Therefore, special attention to quality assurance (QA) procedures is needed in this field. The development of effective and efficient QA programmes is mandatory to guarantee optimal image quality while reducing radiation exposure levels to the ALARA principle (as low as reasonably achievable). In this review article, the basic QA procedures are discussed for the techniques applied to everyday clinical practice.
引用
收藏
页码:1347 / 1354
页数:8
相关论文
共 46 条
[1]
Adams JE, 2008, MED RADIOL DIAGN IMA, P105, DOI 10.1007/978-3-540-68604-0_7
[2]
American College of Radiology, 2008, PRACT GUID TECHN STA, P1
[3]
American Society of Radiologic Technologists, 2009, BON DENS CURR
[4]
Patient-specific microarchitecture of vertebral cancellous bone: A peripheral quantitative computed tomographic and histological study [J].
Banse, X ;
Devogelaer, JP ;
Grynpas, M .
BONE, 2002, 30 (06) :829-835
[5]
Advances in osteoporosis imaging [J].
Bauer, Jan S. ;
Link, Thomas M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (03) :440-449
[6]
Absorbed dose measurements in dual energy X-ray absorptiometry (DXA) [J].
Bezakova, E ;
Collins, PJ ;
Beddoe, AH .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :172-179
[7]
The role of DXA bone density scans in the diagnosis and treatment of osteoporosis [J].
Blake, Glen M. ;
Fogelman, Ignac .
POSTGRADUATE MEDICAL JOURNAL, 2007, 83 (982) :509-517
[8]
The clinical role of dual energy X-ray absorptiometry [J].
Blake, Glen M. ;
Fogelman, Ignac .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (03) :406-414
[9]
Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations [J].
Blake, GM ;
Naeem, M ;
Boutros, M .
BONE, 2006, 38 (06) :935-942
[10]
Total dose incurred by patients and staff from BMD measurement using a new 2D digital bone densitometer [J].
Boudousq, V ;
Kotzki, PO ;
Dinten, JM ;
Barrau, C ;
Robert-Coutant, C ;
Thomas, E ;
Goulart, DM .
OSTEOPOROSIS INTERNATIONAL, 2003, 14 (03) :263-269