Demonstration of feasibility of operating a silicon ZIP detector with 20eV threshold

被引:12
作者
Akerib, DS [1 ]
Dragowsky, M
Driscoll, D
Kamat, S
Perera, T
Schnee, R
Wang, G
Gaitskell, R
Bogdanova, L
Trofimov, V
机构
[1] Case Western Reserve Univ, Cleveland, OH 44106 USA
[2] Brown Univ, Dept Phys, Providence, RI 02806 USA
[3] Inst Theoret & Expt Phys, Moscow 117218, Russia
[4] Joint Inst Nucl Res, Dubna 141980, Russia
关键词
massive cryogenic particle detectors; low-energy threshold; neutrino magnetic moment;
D O I
10.1016/j.nima.2003.11.283
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
100-g silicon detectors (known as "ZIPs," Z-resolving Ionization and Phonon detectors) developed by the Cryogenic Dark Matter Search Experiment have been tested at charge bias voltages of up to 200V/cm, significantly above their usual operating range (similar to3-6 V/cm). Thermal gain factors in excess of 50 were observed due to the primary ionization drifting in the large applied field, with only minimal increase in phonon noise. The observed thermal gain corresponds to an intrinsic threshold of 20eV, resulting in detectors that have direct application for use in a neutrino magnetic moment measurement based on a 40-MCi tritium source. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:163 / 166
页数:4
相关论文
共 5 条
[1]  
BRINK PL, 2002, PHYS REV D, V66
[2]  
CALDWELL DO, HEPPH0305303
[3]   AN APPLICATION OF ELECTROTHERMAL FEEDBACK FOR HIGH-RESOLUTION CRYOGENIC PARTICLE-DETECTION [J].
IRWIN, KD .
APPLIED PHYSICS LETTERS, 1995, 66 (15) :1998-2000
[4]   VOLTAGE-ASSISTED CALORIMETRIC IONIZATION DETECTOR [J].
LUKE, PN .
JOURNAL OF APPLIED PHYSICS, 1988, 64 (12) :6858-6860
[5]  
NEGANOV BS, 1985, Patent No. 1037771