Mixed-gas inductively coupled plasma atomic emission spectrometry using a direct injection high efficiency nebulizer

被引:23
作者
Chirinos, JR [1 ]
Kahen, K [1 ]
O'Brien, SE [1 ]
Montaser, A [1 ]
机构
[1] George Washington Univ, Dept Chem, Washington, DC 20052 USA
基金
美国国家科学基金会;
关键词
direct injection high efficiency nebulizer; DIHEN; mixed-gas inductively coupled plasmas; atomic emission spectrometry; matrix interferences; computer simulation;
D O I
10.1007/s00216-001-1112-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Experimental studies and computer simulations were conducted to identify plasma operating conditions and to explore and contrast the excitation conditions of Ar, Ar-O-2, and Ar-He inductively coupled plasmas (ICPs) for the introduction of microliter volumes of sample solutions with a direct injection high efficiency nebulizer (DIHEN). The best MgII 280.270 nm/MgI 285.213 nm ratio (6.6) measured with Ar ICP atomic emission spectrometry fir the DIHEN (RF power = 1500 W; nebulizer gas flow rate = 0.12 L min(-1)) was less than the ratio (8.2) acquired on the same instrument for conventional nebulization (1500 W and 0.6 L min(-1)), Addition of small amounts of O-2 or He (5%) to the outer gas flow improved excitation conditions in the ICP, that is, a more robust condition (a MgII/MgI ratio of up to 8.9) could be obtained by using the DIHEN with Ar-O-2 and Ar-He mixed-gas plasmas, thereby minimizing some potential spectroscopic and matrix interferences, in comparison to Ar ICPAES.
引用
收藏
页码:128 / 135
页数:8
相关论文
共 47 条
[1]   A large bore-direct injection high efficiency nebulizer for inductively coupled plasma spectrometry [J].
Acon, BW ;
McLean, JA ;
Montaser, A .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1885-1893
[2]   A direct injection high efficiency nebulizer interface for microbore high-performance liquid chromatography-inductively coupled plasma mass spectrometry [J].
Acon, BW ;
McLean, JA ;
Montaser, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (08) :852-857
[3]  
[Anonymous], 1992, INDUCTIVELY COUPLED
[4]   Ultratrace and isotope analysis of long-lived radionuclides by inductively coupled plasma quadrupole mass spectrometry using a direct injection high efficiency nebulizer [J].
Becker, JS ;
Dietze, HJ ;
McLean, JA ;
Montaser, A .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3077-3084
[5]   Universal calibration for analysis of organic solutions by inductively coupled plasma atomic emission spectrometry [J].
Botto, RI ;
Zhu, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :675-681
[6]   APPLICATIONS OF ULTRASONIC NEBULIZATION IN THE ANALYSIS OF PETROLEUM AND PETROCHEMICALS BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
BOTTO, RI .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :51-57
[7]  
BOULOS MI, 1989, HIFI PLASMA COMPUTER
[8]   Axially and radially viewed inductively coupled plasmas - a critical review [J].
Brenner, IB ;
Zander, AT .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (08) :1195-1240
[9]   Comparison of axially and radially viewed inductively coupled plasmas for multi-element analysis: Effect of sodium and calcium [J].
Brenner, IB ;
Zander, A ;
Cole, M ;
Wiseman, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :897-906
[10]   Ca and Na interference effects in an axially viewed ICP using low and high aerosol loadings [J].
Brenner, IB ;
Zischka, M ;
Maichin, B ;
Knapp, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (11) :1257-1264