Components of variance when assessing the reproducibility of body composition measurements using bio-impedance and the Hologic QDR-2000 DXA scanner

被引:17
作者
Jensen, MB
Hermann, AP
Hessov, I
Mosekilde, L
机构
[1] Surgical Research Unit, Department of Surgery L, University Hospital of Aarhus
关键词
D O I
10.1016/S0261-5614(97)80024-6
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
This study evaluated the reproducibility of measuring lean tissue mass (LTM), fat mass (FMDXA), bone mineral content (BMC) and density (BMD) with a Hologic QDR-2000 DXA scanner, and both fat free mass (FFMbio) and fat mass (FMbio) with an impedance meter. Furthermore, the study aimed to assess whether sheets and pillows significantly altered the DXA results. Fifty-one healthy volunteers aged 20-61 years were examined before and after repositioning (n = 20), removal of the sheets (n = 10), addition of two foam pillows (n = 11) or a regular pillow (n = 10). One to 7 days later a re-examination was performed (n = 35). Eight surgical patients were also scanned twice 1-7 days apart. The day to day coefficients of variation were about 1% for most measurements, though more than 2% for FMDXA and FMbio. For total tissue mass, LTM, and BMC there was a significant biological day to day variance whereas for the other measurements the day to day variation could be accounted for by just measurement variance. Pillows systematically changed the estimates of bone mineral and soft tissue, but sheets did not.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 16 条
[1]  
ALTMAN DG, 1991, PRACTICAL STAT MED R, P524
[2]  
Armitage P., 1987, PLANNING STAT INVEST
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
*BSI, 1987, PREC TEST METH DET R, P3
[5]   ASSESSMENT OF THE COMPOSITION OF MAJOR BODY REGIONS BY DUAL-ENERGY X-RAY ABSORPTIOMETRY (DEXA), WITH SPECIAL REFERENCE TO LIMB MUSCLE MASS [J].
FULLER, NJ ;
LASKEY, MA ;
ELIA, M .
CLINICAL PHYSIOLOGY, 1992, 12 (03) :253-266
[6]   DETECTION OF SMALL CHANGES IN BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY [J].
GOING, SB ;
MASSETT, MP ;
HALL, MC ;
BARE, LA ;
ROOT, PA ;
WILLIAMS, DP ;
LOHMAN, TG .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (06) :845-850
[7]   VALIDATION OF BODY-COMPOSITION BY DUAL ENERGY X-RAY ABSORPTIOMETRY (DEXA) [J].
HAARBO, J ;
GOTFREDSEN, A ;
HASSAGER, C ;
CHRISTIANSEN, C .
CLINICAL PHYSIOLOGY, 1991, 11 (04) :331-341
[8]  
HEITMANN BL, 1990, INT J OBESITY, V14, P789
[9]  
JENSEN LB, 1994, J BONE MINER RES, V9, P459
[10]   DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR TOTAL-BODY AND REGIONAL BONE-MINERAL AND SOFT-TISSUE COMPOSITION [J].
MAZESS, RB ;
BARDEN, HS ;
BISEK, JP ;
HANSON, J .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (06) :1106-1112