Safety and Efficacy of Commercially Available Ultrasound Contrast Agents for Rest and Stress Echocardiography A Multicenter Experience

被引:109
作者
Dolan, Melda S. [1 ]
Gala, Simil S. [1 ]
Dodla, Saritha [2 ]
Abdelmoneim, Sahar S. [3 ]
Xie, Feng [2 ]
Cloutier, David [2 ]
Bierig, Michelle [1 ]
Mulvagh, Sharon L. [3 ]
Porter, Thomas R. [2 ]
Labovitz, Arthur J. [1 ]
机构
[1] St Louis Univ, Div Cardiol, St Louis, MO 63110 USA
[2] Univ Nebraska Med Ctr, Cardiol Sect, Omaha, NE USA
[3] Mayo Clin, Div Cardiol, Rochester, MN USA
关键词
echocardiography; contrast; safety; stress; TECHNICALLY DIFFICULT PATIENTS; MYOCARDIAL-INFARCTION; PERFUSION ECHOCARDIOGRAPHY; PROGNOSTIC VALUE; OPACIFICATION; INFUSION; METHODOLOGY; DEFINITION; OPTISON; TRIAL;
D O I
10.1016/j.jacc.2008.08.066
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The authors sought to define the risks versus benefits of ultrasound contrast agents in patients undergoing stress echocardiography. Background The Food and Drug Administration recently placed a "black box" warning on the ultrasound contrast agents Definity (Bristol-Myers Squibb Medical Imaging, Billerica, Massachusetts) and Optison (GE Healthcare, Princeton, New Jersey) after their use was temporally related to 4 deaths. The safety of contrast has not been systematically evaluated. Methods We retrospectively analyzed 42,408 patients at 3 different institutions who had baseline suboptimal images and/or underwent myocardial perfusion imaging and received contrast agents; 18,749 of these underwent stress echocardiography. The outcomes (death and myocardial infarction [MI]) within 30 min, 24 h, and during long-term follow-up were recorded. Results No deaths or MIs were observed within 30 min; 1 death and 5 nonfatal MIs were observed within 24 h. This was not different from a matched cohort of 15,989 patients not receiving contrast. At 1 h and at 30 days after contrast administration, no significant differences in death rates or MIs were observed between patients who did and did not receive contrast during their stress echocardiogram. Endocardial border visualization in patients with suboptimal images resulted in comparable sensitivity (81% vs. 73%, p = NS) and diagnostic accuracy (82% vs. 77%, p = NS) for wall motion analysis compared with patients with optimal image quality. At long- term follow-up, abnormal wall motion and/or myocardial perfusion predicted adverse outcomes (20.6%) when compared with patients with normal studies (3.7%). Conclusions Despite recent warnings regarding echocardiographic contrast, our findings indicate it is a safe and useful diagnostic tool in assessment of patients suspected of having coronary artery disease. (J Am Coll Cardiol 2009; 53: 32-8) (c) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:32 / 38
页数:7
相关论文
共 21 条
[1]   Stress echocardiography: Recommendations for performance and interpretation of stress echocardiography [J].
Armstrong, WF ;
Pellikka, PA ;
Ryan, T ;
Crouse, L ;
Zoghbi, WA .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (01) :97-104
[2]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[3]   Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent - Results of a phase III multicenter trial [J].
Cohen, JL ;
Cheirif, J ;
Segar, DS ;
Gillam, LD ;
Gottdiener, JS ;
Hausnerova, E ;
Bruns, DE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) :746-752
[4]   Echocardiographic imaging of technically difficult patients in the intensive care unit: Use of Optison in combination with fundamental and harmonic imaging [J].
Daniel, GK ;
Chawla, MK ;
Sawada, SG ;
Gradus-Pizlo, I ;
Feigenbaum, H ;
Segar, DS .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (09) :917-920
[5]   Effect of intravenous contrast for left ventricular opacification and border definition on sensitivity and specificity of dobutamine stress echocardiography compared with coronary angiography in technically difficult patients [J].
Dolan, MS ;
Riad, K ;
El-Shafei, A ;
Puri, S ;
Tamirisa, K ;
Bierig, M ;
St Vrain, J ;
McKinney, L ;
Havens, E ;
Habermehl, K ;
Pyatt, L ;
Kern, M ;
Labovitz, AJ .
AMERICAN HEART JOURNAL, 2001, 142 (05) :908-915
[6]   Prognostic value of myocardial viability detected by myocardial contrast echocardiography early after acute myocardial infarction [J].
Dwivedi, Girish ;
Janardhanan, Rajesh ;
Hayat, Sajad A. ;
Swinburn, John M. ;
Senior, Roxy .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (04) :327-334
[7]   Assessment of myocardial perfusion with real-time myocardial contrast echocardiography: Methodology and clinical applications [J].
Elhendy, A ;
Porter, TR .
JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (05) :582-590
[8]   British Cardiac Society Working Group on the definition of myocardial infarction [J].
Fox, KAA ;
Birkhead, J ;
Wilcox, R ;
Knight, C ;
Barth, J .
HEART, 2004, 90 (06) :603-609
[9]   Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography [J].
Geleijnse, ML ;
Fioretti, PM ;
Roelandt, JRTC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :595-606
[10]   Efficacy and safety at the novel ultrasound contrast agent Perflutren (definity) in patients with suboptimal baseline left ventricular echocardiographic images [J].
Kitzman, DW ;
Goldman, ME ;
Gillam, LD ;
Cohen, JL ;
Aurigemma, GP ;
Gottdiener, JS .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (06) :669-674