Potential clinical relevance of digital radiogrammetry for quantification of periarticular bone demineralization in patients suffering from rheumatoid arthritis depending on severity and compared with DXA

被引:52
作者
Böttcher, J
Malich, A
Pfeil, A
Petrovitch, A
Lehmann, G
Heyne, JP
Hein, G
Kaiser, WA
机构
[1] Univ Jena, Inst Diagnost & Intervent Radiol, D-07740 Jena, Germany
[2] Univ Jena, Clin Internal Med 4, Dept Rheumatol & Osteol, D-07747 Jena, Germany
关键词
digital radiogrammetry; DXA; rheumatoid arthritis; bone mineral density;
D O I
10.1007/s00330-003-2087-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to investigate a new bone densitometric technology based on digital radiogrammetry (DXR) with respect to its ability to measure severity-dependent variations of bone mineralization in patients with rheumatoid arthritis. One hundred six randomly selected patients suffering from verified rheumatoid arthritis underwent digitally performed plain radiographs of the non-dominant hand and measurements of dual-energy X-ray absorptiometry (DXA) regarding total femur and lumbar spine. Using DXR the radiographs were analyzed retrospectively for bone mineral density (BMD) calculation. The severity was classified using Larsen score and Steinbroker stage blinded by two radiologists. A third radiologist reviewed the incongruently scored cases. Mean values of calculated parameters changed as follows from Larsen 1 to Larsen 5: Bone mineral density (DXR-BMD) decreased from 0.55 to 0.44 g/cm(2) (p=0.000), DXR-MCI decreased from 0.44 to 0.33 (p=0.001), DXA-BMD (total femur) decreased from 0.92 to 0.78 g/cm(2) (p=0.090) and DXA-BMD (lumbar spine) decreased from 0.91 to 0.84 g/cm(2) (p=0.595). Similar results were verified for the Steinbroker stage. The relative decrease of BMD measured by DXR between the highest and lowest score was 20% for Steinbroker stage and Larsen score (p<0.05). The relative decrease of BMD using DXA revealed not such a significant result. Similar results were verified for metacarpal index (estimated by DXR). Correlations between BMD determined by DXR and by DXA were all significant (R=0.45 for lumbar spine and R=0.59 for total femur). Consequently, less than 35% of the DXR-BMD value is explainable by corresponding DXA values. The DXR-based BMD calculation seems to be able to distinguish severity and progress of the disease in contrast to those of DXA at lumbar spine and total femur.
引用
收藏
页码:631 / 637
页数:7
相关论文
共 38 条
[1]   Computed radiographic absorptiometry and morphometry in the assessment of postmenopausal bone loss [J].
Adami, S ;
Zamberlan, N ;
Gatti, D ;
Zanfisi, C ;
Braga, V ;
Broggini, M ;
Rossini, M .
OSTEOPOROSIS INTERNATIONAL, 1996, 6 (01) :8-13
[2]   THE AMERICAN-RHEUMATISM-ASSOCIATION 1987 REVISED CRITERIA FOR THE CLASSIFICATION OF RHEUMATOID-ARTHRITIS [J].
ARNETT, FC ;
EDWORTHY, SM ;
BLOCH, DA ;
MCSHANE, DJ ;
FRIES, JF ;
COOPER, NS ;
HEALEY, LA ;
KAPLAN, SR ;
LIANG, MH ;
LUTHRA, HS ;
MEDSGER, TA ;
MITCHELL, DM ;
NEUSTADT, DH ;
PINALS, RS ;
SCHALLER, JG ;
SHARP, JT ;
WILDER, RL ;
HUNDER, GG .
ARTHRITIS AND RHEUMATISM, 1988, 31 (03) :315-324
[3]  
Baadegaard N, 2001, BONE, V28, pS176
[4]   Diagnosis and management of osteoporosis: Guidelines for the utilization of bone densitometry [J].
Baran, DT ;
Faulkner, KG ;
Genant, HK ;
Miller, PD ;
Pacifici, R .
CALCIFIED TISSUE INTERNATIONAL, 1997, 61 (06) :433-440
[5]  
BARNETT E, 1960, Clin Radiol, V11, P166, DOI 10.1016/S0009-9260(60)80012-8
[6]   Structure of the femoral neck in hip fracture: Cortical bone loss in the inferoanterior to superoposterior axis [J].
Bell, KL ;
Loveridge, N ;
Power, J ;
Garrahan, N ;
Stanton, M ;
Lunt, M ;
Meggitt, BF ;
Reeve, J .
JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (01) :111-119
[7]   A normative reference database study for Pronosco X-posure System™ [J].
Black, DM ;
Palermo, L ;
Sorensen, T ;
Jorgensen, JT ;
Lewis, C ;
Tylavsky, F ;
Wallace, R ;
Harris, E ;
Cummings, SR .
JOURNAL OF CLINICAL DENSITOMETRY, 2001, 4 (01) :5-12
[8]   A COMPARATIVE ESTIMATION OF THE COMBINED CORTICAL THICKNESS OF VARIOUS BONE SITES [J].
BLOOM, RA .
SKELETAL RADIOLOGY, 1980, 5 (03) :167-170
[9]   The accuracy of peripheral skeletal assessment at the radius in estimating femoral bone density as measured by dual-energy X-ray absorptiometry: a comparative study of single-photon absorptiometry and computed tomography [J].
Boonen, S ;
Cheng, X ;
Nicholson, PHF ;
Verbeke, G ;
Broos, P ;
Dequeker, J .
JOURNAL OF INTERNAL MEDICINE, 1997, 242 (04) :323-328
[10]  
CAMERON EC, 1997, CMAJ, V116, P145