Immunoassays for the measurement of IGF-II, IGFBP-2 and-3, and ICTP as indirect biomarkers of recombinant human growth hormone misuse in sport Values in selected population of athletes
被引:12
作者:
论文数: 引用数:
h-index:
机构:
Abellan, Rosario
[3
,4
]
Ventura, Rosa
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pompeu Fabra, Dept Ciencies Expt & Salut, Barcelona 08003, Spain
Hosp Mar, Inst Municipal Invest Med, Neuropsychopharmacol Program, Bioanal & Analyt Serv Res Grp, Barcelona 08003, SpainIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Ventura, Rosa
[3
,4
]
Palmi, Ilaria
论文数: 0引用数: 0
h-index: 0
机构:
Ist Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, ItalyIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Palmi, Ilaria
[1
]
di Carlo, Simonetta
论文数: 0引用数: 0
h-index: 0
机构:
Ist Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, ItalyIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
di Carlo, Simonetta
[1
]
Bacosi, Antonella
论文数: 0引用数: 0
h-index: 0
机构:
Ist Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, ItalyIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Bacosi, Antonella
[1
]
Bellver, Montse
论文数: 0引用数: 0
h-index: 0
机构:
Ctr Alt Rendiment, Barcelona 08190, SpainIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Bellver, Montse
[2
]
Olive, Ramon
论文数: 0引用数: 0
h-index: 0
机构:
Ctr Alt Rendiment, Barcelona 08190, SpainIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Olive, Ramon
[2
]
Antonio Pascual, Jose
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pompeu Fabra, Dept Ciencies Expt & Salut, Barcelona 08003, Spain
Hosp Mar, Inst Municipal Invest Med, Neuropsychopharmacol Program, Bioanal & Analyt Serv Res Grp, Barcelona 08003, SpainIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Antonio Pascual, Jose
[3
,4
]
Pacifici, Roberta
论文数: 0引用数: 0
h-index: 0
机构:
Ist Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, ItalyIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Pacifici, Roberta
[1
]
Segura, Jordi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pompeu Fabra, Dept Ciencies Expt & Salut, Barcelona 08003, Spain
Hosp Mar, Inst Municipal Invest Med, Neuropsychopharmacol Program, Bioanal & Analyt Serv Res Grp, Barcelona 08003, SpainIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Segura, Jordi
[3
,4
]
Zuccaro, Piergiorgio
论文数: 0引用数: 0
h-index: 0
机构:
Ist Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, ItalyIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Zuccaro, Piergiorgio
[1
]
Pichini, Simona
论文数: 0引用数: 0
h-index: 0
机构:
Ist Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, ItalyIst Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Pichini, Simona
[1
]
机构:
[1] Ist Super Sanita, Dept Therapeut Res & Med Evaluat, I-00161 Rome, Italy
Insulin-like growth factor-II (IGF-II), insulin-like growth factor binding proteins (IGFBPs) -2 and -3 and C-terminal telopeptide of type 1 collagen (ICTP) have been proposed, among others, as indirect biomarkers of the recombinant human growth hormone misuse in sport. An extended intra- and inter-laboratory validation of commercially available immunoassays for biomarkers detection was performed. ELISA assays for total IGF-II, IGFBP-2 and IGFBP-3 (IGF-II/ELISA1: DSLabs, IGFBP-2/ELISA2: Biosource, and IGFBP-3/ELISA3: BioSource) and an EIA assay for ICTP (ICrP/EIA: Orion Diagnostica) were evaluated. The inter- and intro-laboratory precision values were acceptable for all evaluated assays (maximum imprecision of 30% and 66% were found only for the lowest quality control samples of IGF-II and IGFBP-3). Correct accuracy was obtained for all inter-laboratory immunoassays and for IGFBP-2 intro-laboratory immunoassay. The range of concentrations found in serum samples under investigation was always covered by the calibration curves of the studied immunoassays. However, 11% and 15% of the samples felt below the estimated LOQ for IGF-II and ICCP, respectively, in the zone where lower precision was obtained. Although the majority of evaluated assays showed an overall reliability not always suitable for antidoping control analysis, relatively high concordances between laboratory results were obtained for all assays. Evaluated immunoassays were used to measure serum concentrations of IGF-II, IGFBP-2 and -3 and ICTP in elite athletes of various sport disciplines at different moments of the training season; in recreational athletes at baseline conditions and finally in sedentary individuals. Serum IGF-II was statistically higher both in recreational and elite athletes compared to sedentary individuals. Elite athletes showed lower IGFBP-2 and higher IGFBP-3 concentration with respect to recreational athletes and sedentary people. Among elite athletes, serum IGFBP-3 (synchronized swimming), and ICTP (rhythmic gymnastics) concentrations were sport-dependent. Over the training season, within athlete variability was observed for IGFBP-2 in case of taekwondo and IGFBP-2 and -3 in case of weightlifting. Variations due to those aspects should be taken in careful consideration in the hypothesis of setting reference concentration ranges for doping detection. (C) 2008 Elsevier B.V. All rights reserved.