Use of instrumented pedicle screws to evaluate load sharing in posterior dynamic stabilization systems

被引:69
作者
Meyers, Kathleen [1 ]
Tauber, Michael [2 ]
Sudin, Yuri [3 ]
Fleischer, Shai [3 ]
Amin, Uri [3 ]
Girardi, Federico [1 ]
Wright, Timothy [1 ]
机构
[1] Hosp Special Surg, Dept Biomech, New York, NY 10021 USA
[2] Arkade Klin, Spinal Neurosurg Dept, D-98597 Breitungen, Germany
[3] Impliant Ltd, Ramat Poleg, Israel
关键词
Pedicle screw; Lumbar; Posterior stabilization;
D O I
10.1016/j.spinee.2007.08.008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Dynamic stabilization is an alternative to fusion intended to eliminate or at least minimize the potential for adjacent level degeneration. Different design approaches are used in pedicle screw-based systems that should have very different effects on the loading of the posterior column and intervertebral disc. If the implant system distributes these loads more evenly, loads in the pedicle screws will be reduced, and screw loosening will be prevented. PURPOSE: The purpose of this study was to determine how two different design approaches to dynamic stabilization systems, Dynesys System and the Total Posterior Spine (TOPS) System, affect the load carried by the pedicle screws. STUDY DESIGN/SETTING: A controlled laboratory study in which the magnitude of the moments on pedicle screws during flexion-extension and lateral bending were measured after implantation of two posterior dynamic stabilization devices into cadaveric spines. METHODS: Five lumbar spines were tested in flexion-extension and lateral bending. Specimens were tested sequentially: first intact, then with the Dynesys system implanted, and finally with the TOPS system implanted. Range of motion (ROM) for each construct was measured with a 210 N and 630 N compressive load. The pedicle screws were instrumented with strain gages, which were calibrated so that the moments on the screws could be determined from the strain measurements. RESULTS: Compared with intact values, ROM decreased in flexion-extension and lateral bending when the Dynesys System was implanted. With implantation of the TOPS System, ROM returned to values that were not significantly different from the intact values. The moments in the screws with the Dynesys System were significantly higher than with the TOPS System with increases of as much as 56% in flexion-extension and 86% in lateral bending. CONCLUSIONS: The design of the posterior stabilization device influences the amount of load seen by the pedicle screws and therefore the load sharing between spinal implant and bone. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:926 / 932
页数:7
相关论文
共 20 条
[1]
BIOMECHANICAL ANALYSIS OF PEDICLE SCREW INSTRUMENTATION SYSTEMS IN A CORPECTOMY MODEL [J].
ASHMAN, RB ;
GALPIN, RD ;
CORIN, JD ;
JOHNSTON, CE .
SPINE, 1989, 14 (12) :1398-1405
[2]
ASHMAN RB, 1988, CLIN ORTHOP RELAT R, P113
[3]
Bordes-Monmeneu M, 2005, NEUROCIRUGIA, V16, P499
[4]
INTERNAL FORCES AND MOMENTS IN TRANSPEDICULAR SPINE INSTRUMENTATION - THE EFFECT OF PEDICLE SCREW ANGLE AND TRANSFIXATION - THE 4R-4BAR LINKAGE CONCEPT [J].
CARSON, WL ;
DUFFIELD, RC ;
ARENDT, M ;
RIDGELY, BJ ;
GAINES, RW .
SPINE, 1990, 15 (09) :893-901
[5]
Eck J C, 1999, Am J Orthop (Belle Mead NJ), V28, P336
[6]
Dynamic neutralisation of the lumbar spine confirmed on a new lumbar spine simulator in vitro [J].
Freudiger, S ;
Dubois, G ;
Lorrain, M .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1999, 119 (3-4) :127-132
[7]
Clinical experience with the Dynesys semirigid fixation system for the lumbar spine - Surgical and patient-oriented outcome in 50 cases after an average of 2 years [J].
Grob, D ;
Benini, A ;
Junge, A ;
Mannion, AF .
SPINE, 2005, 30 (03) :324-331
[8]
LARGE COMPRESSIVE PRELOADS DECREASE LUMBAR MOTION SEGMENT FLEXIBILITY [J].
JANEVIC, J ;
ASHTONMILLER, JA ;
SCHULTZ, AB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (02) :228-236
[9]
KOSTUIK JP, 1994, J SPINAL DISORD, V7, P394
[10]
ACCELERATED DEGENERATION OF THE SEGMENT ADJACENT TO A LUMBAR FUSION [J].
LEE, CK .
SPINE, 1988, 13 (03) :375-377