Rapid diagnosis of infected ascitic fluid using leukocyte esterase dipstick testing

被引:41
作者
Butani, RC
Shaffer, RI
Szyjkowski, RD
Weeks, BE
Speights, LG
Kadakia, SC
机构
[1] San Antonio Uniformed Serv Hlth Educ Consortium, Brooke Army Med Ctr, Dept Pathol & Lab Serv, San Antonio, TX USA
[2] San Antonio Uniformed Serv Hlth Educ Consortium, Brooke Army Med Ctr, Dept Med, Div Gastroenterol, San Antonio, TX USA
[3] SUNY Syracuse, Upstate Med Ctr, Div Gastroenterol, Dept Med, Syracuse, NY USA
关键词
D O I
10.1111/j.1572-0241.2004.04084.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives: Ascitic fluid infection is presumptively diagnosed when the fluid polymorphonuclear leukocyte (PMN) concentration equals or exceeds 250 cells/mul. The leukocyte esterase (LE) test has been shown to be a good predictor of the presence of PMNs and bacteria in urine and other body fluids. This study examines the value of the Multistix(R) 10 SG LE Dipstick test for the rapid diagnosis of infected ascitic fluid. Methods: One hundred thirty-six ascitic fluid samples were evaluated by PMN count, culture, and LE Dipstick testing. LE dipstick values of "small" or greater were considered positive. For each sample, the LE test result was compared to the corresponding PMN count and culture result. Results: Ten of the 11 LE-positive samples had PMN greater than or equal to250 cells/mul, while 10 of 12 samples with PMN greater than or equal to250 cells/mul were also LE-positive. Of the 125 LE-negative samples, 123 were also negative by PMN count. One hundred twenty-three of the 124 samples with PMN <250 cells/mu l had negative LE tests. There was a less concordant relationship between the LE test and culture results. The sensitivity and specificity of the LE test for detecting ascitic fluid PMN >= 250 cells/mu l were 83% and 99%, respectively, with a positive predictive value of 91% and a negative predictive value of 98%. Conclusions: The Multistix(R) leukocyte esterase test is useful for the prompt detection of an elevated ascitic fluid PMN count, and represents a convenient new method for the rapid diagnosis of infected ascitic fluid.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 28 条
  • [1] Rapid diagnosis of infectious pleural effusions by use of reagent strips
    Azoulay, E
    Fartoukh, M
    Galliot, R
    Baud, F
    Simonneau, G
    Le Gall, JR
    Schlemmer, B
    Chevret, S
    [J]. CLINICAL INFECTIOUS DISEASES, 2000, 31 (04) : 914 - 919
  • [2] SPONTANEOUS BACTERIAL PERITONITIS - AN UPDATE ON EVALUATION, MANAGEMENT, AND PREVENTION
    BHUVA, M
    GANGER, D
    JENSEN, D
    [J]. AMERICAN JOURNAL OF MEDICINE, 1994, 97 (02) : 169 - 175
  • [3] Use of Multistix® leukocyte esterase dipstick testing for ascitic fluid infection.
    Butani, RC
    Shaffer, RT
    Szyjkowski, RD
    Weeks, BE
    Speights, LG
    Kadakia, SC
    [J]. GASTROENTEROLOGY, 2000, 118 (04) : A979 - A979
  • [4] Rapid diagnosis of spontaneous bacterial peritonitis by use of reagent strips
    Castellote, J
    López, C
    Gornals, J
    Tremosa, G
    Fariña, ER
    Baliellas, C
    Domingo, A
    Xiol, X
    [J]. HEPATOLOGY, 2003, 37 (04) : 893 - 896
  • [5] Chacko M R, 1996, J Pediatr Adolesc Gynecol, V9, P185
  • [6] THE LEUKOCYTE ESTERASE TEST FOR DETECTION OF CEREBROSPINAL-FLUID LEUKOCYTOSIS AND BACTERIAL-MENINGITIS
    DELOZIER, JS
    AUERBACH, PS
    [J]. ANNALS OF EMERGENCY MEDICINE, 1989, 18 (11) : 1191 - 1198
  • [7] NONINVASIVE SAMPLING FOR DETECTION OF GENITAL-INFECTION WITH CHLAMYDIA-TRACHOMATIS IN MALES UTILIZING URINARY LEUKOCYTE ESTERASE TESTS AND IMMUNOASSAYS
    DOMEIKA, MA
    BASSIRI, M
    MARDH, PA
    [J]. INFECTION, 1994, 22 (02) : 65 - 68
  • [8] LEUKOCYTE ESTERASE - A SIMPLE BEDSIDE TEST FOR THE DETECTION OF BACTERIAL-COLONIZATION OF AMNIOTIC-FLUID
    EGLEY, CC
    KATZ, VL
    HERBERT, WNP
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1988, 159 (01) : 120 - 122
  • [9] Farmer CKT, 2000, PERITON DIALYSIS INT, V20, P237
  • [10] ISSELBACHER KJ, 1995, HARRISONS PRINCIPLES