Quartz crystal microbalance sensor coated with polyaniline emeraldine base for determination of chlorinated aliphatic hydrocarbons

被引:51
作者
Ayad, Mohamad M. [1 ]
El-Hefnawey, Gad [1 ]
Torad, Nagy L. [1 ]
机构
[1] Tanta Univ, Fac Sci, Dept Chem, Tanta, Egypt
关键词
Quartz crystal microbalance; Polyaniline emeraldine base; Sensor; Organic vapours;
D O I
10.1016/j.snb.2008.06.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A quartz crystal microbalance (QCM) sensor coated with a thin film of polyaniline emeraldine base (EB) was used as a sensitive method for the determination of a number of aliphatic chlorinated hydrocarbons such as carbon tetrachloride, chloroform, dichloromethane, 1,2-dichloroethane vapours. The detection was based on the absorption of the vapours of these organic compounds into the EB film. The frequency shifts due to the absorption of the chlorinated hydrocarbons were measured and calibration curves were plotted. The detection of these vapours can be obtained in part per million (ppm). The work includes also the use of a polyaniline emeraldine salt (ES) film instead of the EB film. It is concluded that the EB film has higher sensitivity towards the organic vapours than the ES film, which can be attributed to the presence of unprotonated amine and imine groups along the polyaniline (PANI) chains in the EB form, (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:887 / 894
页数:8
相关论文
共 56 条
[1]   An optical gas sensor based on polyaniline Langmuir-Blodgett films [J].
Agbor, NE ;
Cresswell, JP ;
Petty, MC ;
Monkman, AP .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 41 (1-3) :137-141
[2]   POLYANILINE THIN-FILMS FOR GAS-SENSING [J].
AGBOR, NE ;
PETTY, MC ;
MONKMAN, AP .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 28 (03) :173-179
[3]   OPTIMUM REACTION CONDITIONS FOR THE POLYMERIZATION OF ANILINE IN AQUEOUS-SOLUTION BY AMMONIUM PERSULFATE [J].
ARMES, SP ;
MILLER, JF .
SYNTHETIC METALS, 1988, 22 (04) :385-393
[4]   Polyaniline and its substituted derivatives as sensor for aliphatic alcohols [J].
Athawale, AA ;
Kulkarni, MV .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :173-177
[5]   pH sensor based on polyaniline and aniline-anthranilic acid copolymer films using quartz crystal microbalance and electronic absorption spectroscopy [J].
Ayad, M. M. ;
Salahuddin, N. A. ;
Abou-Seif, A. K. ;
Alghaysh, M. O. .
POLYMERS FOR ADVANCED TECHNOLOGIES, 2008, 19 (08) :1142-1148
[6]   Determination of the dopant weight fraction in polyaniline films using a quartz-crystal microbalance [J].
Ayad, M. M. ;
Zaki, E. A. ;
Stejskal, J. .
THIN SOLID FILMS, 2007, 515 (23) :8381-8385
[7]   Optimum reaction conditions for in situ polyaniline films [J].
Ayad, MM ;
Salahuddin, N ;
Sheneshin, MA .
SYNTHETIC METALS, 2003, 132 (02) :185-190
[8]  
AYAD MM, THIN SOLID FIL UNPUB
[9]   Quartz crystal microbalance and spectroscopy measurements for acid doping in polyaniline films [J].
Ayad, Mohamad M. ;
Zaki, Eman A. .
SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2008, 9 (01)
[10]   CONDUCTING POLYMER GAS SENSORS .3. RESULTS FOR 4 DIFFERENT POLYMERS AND 5 DIFFERENT VAPORS [J].
BARTLETT, PN ;
LINGCHUNG, SK .
SENSORS AND ACTUATORS, 1989, 20 (03) :287-292