Robust pupil center detection using a curvature algorithm

被引:92
作者
Zhu, DJ
Moore, ST
Raphan, T
机构
[1] CUNY Brooklyn Coll, Dept Comp & Informat Sci, Brooklyn, NY 11210 USA
[2] CUNY Mt Sinai Sch Med, Dept Neurol, New York, NY 10029 USA
关键词
eye movements; video; VOG; image processing; VOR;
D O I
10.1016/S0169-2607(98)00105-9
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Determining the pupil center is fundamental for calculating eye orientation in video-based systems. Existing techniques are error prone and not robust because eyelids, eyelashes, corneal reflections or shadows in many instances occlude the pupil. We have developed a new algorithm which utilizes curvature characteristics of the pupil boundary to eliminate these artifacts. Pupil center is computed based solely on points related to the pupil boundary. For each boundary point, a curvature value is computed. Occlusion of the boundary induces characteristic peaks in the curvature function. Curvature values for normal pupil sizes were determined and a threshold was found which together with heuristics discriminated normal from abnormal curvature. Remaining boundary points were fit with an ellipse using a least squares error criterion. The center of the ellipse is an estimate of the pupil center. This technique is robust and accurately estimates pupil center with less than 40% of the pupil boundary points visible. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:145 / 157
页数:13
相关论文
共 29 条
  • [1] Ballard D.H., 1982, Computer Vision
  • [2] BARBUR JL, 1987, CLIN VISION SCI, V2, P131
  • [3] OCULAR TORSION QUANTIFICATION WITH VIDEO IMAGES
    BOS, JE
    DEGRAAF, B
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (04) : 351 - 357
  • [4] NEW INSTRUMENT FOR MONITORING EYE FIXATION AND PUPIL SIZE DURING THE VISUAL-FIELD EXAMINATION
    CHARLIER, JR
    HACHE, JC
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (01) : 23 - 28
  • [5] CLARKE AH, 1991, STUD VIS INFORM PROC, V2, P431
  • [6] Clarke AH, 1994, EYE MOVEMENTS READIN, P21
  • [7] LEAST-SQUARES FITTING OF CIRCLES AND ELLIPSES
    GANDER, W
    GOLUB, GH
    STREBEL, R
    [J]. BIT, 1994, 34 (04): : 558 - 578
  • [8] Determination of ocular torsion by means of automatic pattern recognition
    Groen, E
    Bos, JE
    Nacken, PFM
    deGraaf, B
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (05) : 471 - 479
  • [9] THEORETICAL-ANALYSIS OF 3-DIMENSIONAL EYE POSITION MEASUREMENT USING POLAR CROSS-CORRELATION
    HASLWANTER, T
    MOORE, ST
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (11) : 1053 - 1061
  • [10] DESIGN CONSIDERATIONS FOR A REAL-TIME OCULAR COUNTERROLL INSTRUMENT
    HATAMIAN, M
    ANDERSON, DJ
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (05) : 278 - 288