摘要
The purpose of this experiment was to assess the test-retest reliability of input-output parameters of the cortico-spinal pathway derived from transcranial magnetic (TMS) and electrical (TES) stimulation at rest and during muscle contraction. Motor evoked potentials (MEPs) were recorded from the first dorsal interosseous muscle of eight individuals on three separate days. The intensity of TMS at rest was varied from 5% below threshold to the maximal output of the stimulator. During trials in which the muscle was active, TMS and TES intensities were selected that elicited MEPs of between 150 and 300 X at rest. MEPs were evoked while the participants exerted torques up to 50% of their maximum capacity. The relationship between MEP size and stimulus intensity at rest was sigmoidal (R-2 = 0.97). Intra-class correlation coefficients (ICC) ranged between 0.47 and 0.81 for the parameters of the sigmoid function. For the active trials, the slope and intercept of regression equations of MEP size on level of background contraction were obtained more reliably for TES (ICC = 0.63 and 0.78, respectively) than for TMS (ICC = 0.50 and 0.53, respectively), These results suggest that input-output parameters of the cortico-spinal pathway may be reliably obtained via transcranial stimulation during longitudinal investigations of cortico-spinal plasticity. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 23 条
[1]  
BERARDELLI A, 1991, ELECTROEN CLIN NEURO, P147
[2]   Studies on the corticospinal control of human walking. I. Responses to focal transcranial magnetic stimulation of the motor cortex [J].
Capaday, C ;
Lavoie, BA ;
Barbeau, H ;
Schneider, C ;
Bonnard, M .
JOURNAL OF NEUROPHYSIOLOGY, 1999, 81 (01) :129-139
[3]   Neurophysiological methods for studies of the motor system in freely moving human subjects [J].
Capaday, C .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 74 (02) :201-218
[4]  
CAPADAY C, 1986, J NEUROSCI, V6, P1308
[5]   DIFFERENCE IN THE AMPLITUDE OF THE HUMAN SOLEUS H REFLEX DURING WALKING AND RUNNING [J].
CAPADAY, C ;
STEIN, RB .
JOURNAL OF PHYSIOLOGY-LONDON, 1987, 392 :513-522
[6]  
Carroll T J, 2001, Exerc Sport Sci Rev, V29, P54
[7]   Input-output properties and gain changes in the human corticospinal pathway [J].
Devanne, H ;
Lavoie, BA ;
Capaday, C .
EXPERIMENTAL BRAIN RESEARCH, 1997, 114 (02) :329-338
[8]  
Di Lazzaro V, 1998, J PHYSIOL-LONDON, V508, P625
[9]   Comparison of activation of corticospinal neurons and spinal motor neurons by magnetic and electrical transcranial stimulation in the lumbosacral cord of the anaesthetized monkey [J].
Edgley, SA ;
Eyre, JA ;
Lemon, RN ;
Miller, S .
BRAIN, 1997, 120 :839-853
[10]   Enhancing the quality of studies using transcranial magnetic and electrical stimulation with a new computer-controlled system [J].
Kaelin-Lang, A ;
Cohen, LG .
JOURNAL OF NEUROSCIENCE METHODS, 2000, 102 (01) :81-89