Removal of nutrients from combined sewer overflows and lake water in a vertical-flow constructed wetland system

被引:27
作者
Gervin, L
Brix, H
机构
[1] Dept Environm, Copenhagen Water, DK-1554 Copenhagen, Denmark
[2] Univ Aarhus, Dept Plant Ecol, DK-8240 Risskov, Denmark
关键词
combined sewer overflow; constructed wetland; nitrogen; phosphorus; stormwater; urban runoff; vertical-flow system; water treatment;
D O I
10.2166/wst.2001.0825
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Lake Utterslev is situated in a densely built-up area of Copenhagen, and is heavily eutrophicated from combined sewer overflows, At the same time the lake suffers from lack of water. Therefore, a 5,000 m(2) vertical flow wetland system was constructed in 1998 to reduce the phosphorus discharge from combined sewer overflows without reducing the water supply to the lake. During dry periods the constructed wetland is used to remove phosphorus from the lake water. The system is designed as a 90 m diameter circular bed with a bed depth of c. 2 m. The system is isolated from the surroundings by a polyethylene membrane. The bed medium consists of a mixture of gravel and crushed marble, which has a high binding capacity for phosphorus. The bed is located within the natural littoral zone of the lake and is planted with common reed (Phragmites australis). The constructed wetland is intermittently loaded with combined sewer overflow water or lake water and, after percolation through the bed medium, the water is collected in a network of drainage pipes at the bottom of the bed and pumped to the lake. The fully automated loading cycle results in alternating wet and dry periods. During the initial two years of operation, the phosphorus removal for combined sewer overflows has been consistently high (94-99% of inflow concentrations). When loaded with lake water, the phosphorus removal has been high during summer (71-97%) and lower during winter (53-75%) partly because of lower inlet concentrations. Effluent phosphorus concentrations are consistently low (0.03-0.04 mg/L). Ammonium nitrogen is nitrified in the constructed wetland, and total suspended solids and COD are generally reduced to concentrations below 5 mg/L and 25 mg/L, respectively. The study documents that a subsurface flow constructed wetland system can be designed and operated to effectively remove phosphorus and other pollutants from combined sewer overflows and eutrophicated lake water.
引用
收藏
页码:171 / 176
页数:6
相关论文
共 6 条
[1]   Media selection for sustainable phosphorus removal in subsurface flow constructed wetlands [J].
Brix, H ;
Arias, CA ;
del Bubba, M .
WATER SCIENCE AND TECHNOLOGY, 2001, 44 (11-12) :47-54
[2]   Treatment of combined sewer overflows at small wastewater treatment works by constructed reed beds [J].
Green, MB ;
Martin, JR ;
Griffin, P .
WATER SCIENCE AND TECHNOLOGY, 1999, 40 (03) :357-364
[3]  
*MUN COP, 2000, NOVA2003 MUNC COP AQ
[4]   The removal of urban pollutants by constructed wetlands during wet weather [J].
Scholes, LNL ;
Shutes, RBE ;
Revitt, DM ;
Purchase, D ;
Forshaw, M .
WATER SCIENCE AND TECHNOLOGY, 1999, 40 (03) :333-340
[5]  
SEEHUUSEN M, 2000, STADS HAVNEINGENIORE, P4
[6]   The design of wetland systems for the treatment of urban run off [J].
Shutes, RBE ;
Revitt, DM ;
Mungur, AS ;
Scholes, LNL .
WATER SCIENCE AND TECHNOLOGY, 1997, 35 (05) :19-25