Erythrocyte viability in blood salvaged during total joint arthroplasty with cement

被引:26
作者
Colwell, CW [1 ]
Beutler, E [1 ]
West, C [1 ]
Hardwick, ME [1 ]
Morris, BA [1 ]
机构
[1] Scripps Res Inst, La Jolla, CA 92037 USA
关键词
D O I
10.2106/00004623-200201000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Erythrocyte salvage, the collection of a patient's blood shed from the surgical wound, is one aspect of blood management. Previous investigators have examined salvaged blood for content; however, to our knowledge, none have examined the viability of erythrocytes after exposure to the chemical and thermal reactions produced by motorized instruments and polymethylmethacrylate during surgery. The purpose of this study was to determine the viability of salvaged erythrocytes from patients undergoing primary total joint arthroplasty with cement. Methods: Erythrocyte viability studies were performed on specimens from three subjects with use of a double isotope-labeling technique employing chromium-51 and technetium-99m. With use of a fresh blood specimen obtained prior to surgery and a specimen of salvaged blood that had been recycled, washed, and filtered with use of the Cell Saver, the viability of the Cell-Saver-processed erythrocytes, labeled with chromium-51, was calculated on the basis of the technetium-99m-labeled red blood-cell mass. Results: The mean erythrocyte viability (and standard deviation) in blood salvaged with use of the Cell Saver was 88.0% +/- 3.8%. The standard of the American Association of Blood Banks for minimum erythrocyte viability in adequately cross-matched allogeneic blood or predeposited autologous blood is 70%. Conclusions: The high rate of viability of the erythrocytes in this study shows that the Cell Saver is a valuable adjunct to other blood management techniques for patients having total joint arthroplasty. We believe that the very high mean rate of erythrocyte viability and the extremely small standard deviation in our three subjects, as compared with the standards of the American Association of Blood Banks, made additional study subjects unnecessary.
引用
收藏
页码:23 / 25
页数:3
相关论文
共 23 条
[1]
ANSELL J, 1982, J THORAC CARDIOV SUR, V84, P387
[2]
MEASUREMENT OF THE VIABILITY OF STORED RED-CELLS BY THE SINGLE-ISOTOPE TECHNIQUE USING CR-51 - ANALYSIS OF VALIDITY [J].
BEUTLER, E ;
WEST, C .
TRANSFUSION, 1984, 24 (02) :100-104
[3]
BLAYLOCK RC, 1994, AM J CLIN PATHOL, V101, P365
[4]
Cone J, 1990, Instr Course Lect, V39, P431
[5]
COWELL HR, 1989, J BONE JOINT SURG AM, V71A, P1
[6]
CELL QUALITY OF SALVAGED BLOOD AFTER TOTAL KNEE ARTHROPLASTY - DRAIN BLOOD COMPARED TO VENOUS-BLOOD IN 32 PATIENTS [J].
DALEN, T ;
BROSTROM, LA ;
ENGSTROM, KG .
ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (04) :329-333
[7]
Autotransfusion after total knee arthroplasty - Effects on blood cells, plasma chemistry, and whole blood rheology [J].
Dalen, T ;
Brostrom, LA ;
Engstrom, KG .
JOURNAL OF ARTHROPLASTY, 1997, 12 (05) :517-525
[8]
UNWASHED FILTERED SHED BLOOD COLLECTED AFTER KNEE AND HIP ARTHROPLASTIES - A SOURCE OF AUTOLOGOUS RED-BLOOD-CELLS [J].
FARIS, PM ;
RITTER, MA ;
KEATING, EM ;
VALERI, CR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (08) :1169-1178
[9]
Gannon D M, 1991, J Arthroplasty, V6, P109, DOI 10.1016/S0883-5403(11)80004-5
[10]
INTRAOPERATIVE AUTOLOGOUS TRANSFUSION IN ORTHOPEDIC PATIENTS [J].
GOULET, JA ;
BRAY, TJ ;
TIMMERMAN, LA ;
BENSON, DR ;
BARGAR, WL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (01) :3-8