Bronchodilator delivery with metered-dose inhalers in mechanically-ventilated patients

被引:44
作者
Dhand, R [1 ]
Tobin, MJ [1 ]
机构
[1] LOYOLA UNIV,STRITCH SCH MED,HINES,IL
关键词
aerosols; mechanical ventilation; nebulizers; pulmonary mechanics;
D O I
10.1183/09031936.96.09030585
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Metered-dose inhalers (MDIs) provide several advantages over nebulizers, including ease of administration, decreased cost, reliability of dosing, and freedom from contamination. However, this method of aerosol delivery has been considered ineffective in mechanically-ventilated patients because most of the aerosol deposits in the endotracheal tube and ventilator circuit. A smaller amount of aerosol from a MDI is deposited in the lower respiratory tract of mechanically-ventilated patients than in ambulatory patients, although recent studies show that a significant bronchodilator effect can still be achieved, When employed optimally, significant bronchodilation occurs with as little as 4 puffs of a sympathomimetic aerosol, Multiple factors influence the efficacy of MDIs in mechanically-ventilated patients. The method of connecting the MDI canister to the ventilator circuit has a marked effect on aerosol delivery, and other factors include the timing of MDI actuation, ventilator mode, tidal volume, circuit humidity, and duty cycle, With a proper technique of administration, a MDI serves as an effective, convenient, and safe method for delivering bronchodilator aerosols in mechanically-ventilated patients.
引用
收藏
页码:585 / 595
页数:11
相关论文
共 69 条
[1]   DISPOSABLE JET NEBULIZERS - HOW RELIABLE ARE THEY [J].
ALVINE, GF ;
RODGERS, P ;
FITZSIMMONS, KM ;
AHRENS, RC .
CHEST, 1992, 101 (02) :316-319
[2]  
[Anonymous], 1966, HEALTH PHYS
[3]   THE FLOW INTERRUPTION TECHNIQUE FOR MEASURING RESPIRATORY RESISTANCE [J].
BATES, JHT ;
MILICEMILI, J .
JOURNAL OF CRITICAL CARE, 1991, 6 (04) :227-238
[4]   ANALYSIS OF THE BEHAVIOR OF THE RESPIRATORY SYSTEM WITH CONSTANT INSPIRATORY FLOW [J].
BATES, JHT ;
ROSSI, A ;
MILICEMILI, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (06) :1840-1848
[5]   COMPARISON OF SOME METHODS FOR MEASURING TOTAL RESPIRATORY RESISTANCE [J].
BERGMAN, NA ;
WALTEMATH, CL .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 36 (01) :131-134
[6]  
BERNASCONI M, 1990, INTENS CARE MED, V16, P108, DOI 10.1007/BF02575304
[7]   METERED DOSE INHALER AEROSOL CHARACTERISTICS ARE AFFECTED BY THE ENDOTRACHEAL-TUBE ACTUATOR ADAPTER USED [J].
BISHOP, MJ ;
LARSON, RP ;
BUSCHMAN, DL .
ANESTHESIOLOGY, 1990, 73 (06) :1263-1265
[8]  
Bleecker ER, 1995, AM J RESP CRIT CARE, V151, pA58
[9]   DRUG-USE IN A TRAUMA INTENSIVE-CARE UNIT [J].
BOUCHER, BA ;
KUHL, DA ;
COFFEY, BC ;
FABIAN, TC .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1990, 47 (04) :805-810
[10]   SUBSTITUTION OF METERED-DOSE INHALERS FOR HAND-HELD NEBULIZERS - SUCCESS AND COST SAVINGS IN A LARGE, ACUTE-CARE HOSPITAL [J].
BOWTON, DL ;
GOLDSMITH, WM ;
HAPONIK, EF .
CHEST, 1992, 101 (02) :305-308