Measurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting

被引:71
作者
Bridge, PD [1 ]
Ranganathan, S [1 ]
McKenzie, SA [1 ]
机构
[1] Royal London Hosp, Queen Elizabeth Childrens Serv, London E1 1BB, England
关键词
interrupter technique; lung function; preschool asthma;
D O I
10.1034/j.1399-3003.1999.13d16.x
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
This study describes the feasibility, repeatability, and interrater reliability of the measurement of airway resistance by the interrupter technique (Rint) in children 2-5 yrs of age, and examines whether reversibility to bronchodilator can be demonstrated in wheezy children. The mean of six Rint values was taken as a measurement. If subjects could complete one measurement and then a second 15 min after bronchodilator, baseline testing and reversibility testing were considered feasible. To measure repeatability, two measurements 30 s apart and measurements before and 15 min after placebo bronchodilator were compared. Measurements by two testers were compared for interrater reliability. Change in Rint in wheezy children was measured after bronchodilator. Fifty-six per cent of 2-3-yr-olds (n=79), 81% of 3-4-yr-olds (n=104) and 95% of 4-5-yr-olds (n=88) completed baseline testing, and 53%, 71% and 91% completed reversibility testing. Baseline measurements were 0.47-2.56 kPa.L-1.s. Repeatabilities (2 SD of the mean differences between measurements) at 30 s in the three age bands were 0.21, 0.17 and 0.15 kPa.L-1.s and 0.19 kPa.L-1.s after placebo. Using 0.21 kPa.L-1.s as the threshold for reversibility, reversibility was demonstrated in most wheezy children. Interrater reliability was 0.15 kPa.L-1.s. Preschool children can undertake measurements of airway resistance by the interrupter technique in ambulatory settings and reversibility to bronchodilator in wheezy children can be demonstrated. This technique promises to be a useful clinical and research tool.
引用
收藏
页码:792 / 796
页数:5
相关论文
共 15 条
  • [1] ALLEN JL, 1993, AM REV RESPIR DIS, V147, P474
  • [2] MEASUREMENT OF ALVEOLAR PRESSURE IN CLOSED-CHEST DOGS DURING FLOW INTERRUPTION
    BATES, JHT
    ABE, T
    ROMERO, PV
    SATO, J
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (01) : 488 - 492
  • [3] BATES JHT, 1987, RESP PHYSIOL, V70, P301, DOI 10.1016/S0034-5687(87)80052-X
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] A portable device based on the interrupter technique to measure bronchodilator response in schoolchildren
    Bridge, PD
    Lee, H
    Silverman, M
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (07) : 1368 - 1373
  • [6] EVALUATION OF THE INTERRUPTER TECHNIQUE FOR THE USE OF ASSESSING AIRWAY-OBSTRUCTION IN CHILDREN
    CARTER, ER
    STECENKO, AA
    POLLOCK, BH
    JAEGER, MJ
    [J]. PEDIATRIC PULMONOLOGY, 1994, 17 (04) : 211 - 217
  • [7] Carter ER, 1997, EUR RESPIR J, V10, P1428
  • [8] COUGH, WHEEZE AND ASTHMA DIAGNOSIS IN CHILDREN
    JONES, KP
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 1993, 23 (08) : 627 - 628
  • [9] Klug B, 1998, PEDIATR PULM, V25, P322, DOI 10.1002/(SICI)1099-0496(199805)25:5<322::AID-PPUL6>3.0.CO
  • [10] 2-K