Nosocomial infections in a medical-surgical intensive care unit

被引:51
作者
Aly, Nasser Yehia A. [1 ,3 ]
Al-Mousa, Haifaa H. [1 ]
Al Asar, El Sayed M. [2 ]
机构
[1] Farwaniya Hosp, Minist Hlth, Dept Infect Control, Al Shamiya 71655, Kuwait
[2] Farwaniya Hosp, Minist Hlth, Dept Microbiol, Al Shamiya 71655, Kuwait
[3] Univ Alexandria, Fac Med, Dept Trop Med & Hyg, Alexandria, Egypt
关键词
nosocomial infection; intensive care unit; device-associated infection;
D O I
10.1159/000141500
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We aimed to describe the pattern of nosocomial infections in an adult medical-surgical intensive care unit (ICU). Subjects and Methods: A 2-year prospective cohort study of nosocomial infection surveillance in a 15-bed adult combined medical and surgical ICU of Farwaniya Hospital, Kuwait, was carried out. Data were collected between January 2004 and December 2005 using the standard surveillance protocols and nosocomial infection site definitions of the National Nosocomial Infections Surveillance System's ICU surveillance component. Results: Of 1,173 patients hospitalized in the ICU for an aggregate duration of 6,855 days, 89 patients acquired a total of 140 nosocomial infections; 46 (33%) ventilator-associated pneumonia (VAP), 33 (24%) centralline-associated bloodstream infection and 15 (11%) catheter-associated urinary tract infection, 22 (16%) cutaneous infection and 24 (17%) other infections. The overall patient day rate was 20.6/1,000 patient days. The patient infection rate was 10.6/100 patients at risk. The mean VAP rate was 9.1/1,000 ventilator days (95% CI, 5-13.2), the central-line-associated bloodstream infection rate 5.5/1,000 central line days ( 95% CI, 3.2-7.8) and the catheter-associated urinary tract infection rate 2.3/1,000 catheter days ( 95% CI, 1.2-3.4). Of all nosocomial infections, 119 (85%)were culture-confirmed and 21 (15%) were clinically defined culture-negative infections. Of the culture-confirmed nosocomial infections, 81 (68%) were Gram-negative, 32 (27%) Gram-positive and 6 (5%) fungal. The most frequent organism was Pseudomonas aeruginosa (20, 17%), followed by Acinetobacter baumannii (15, 13%), Klebsiella spp. (13, 11%) and Escherichia coli (10, 8%). The crude mortality was 27% among ICU-infected patients. Conclusion: VAP was the most common nosocomial infection in our ICU. Gram-negative organisms were more commonly reported as etiologic agents of ICU infections. Copyright (c) 2008 S. Karger AG, Basel.
引用
收藏
页码:373 / 377
页数:5
相关论文
共 23 条
  • [1] Drug resistance in intensive care units
    Albrich, WC
    Angstwurm, M
    Bader, L
    Gärtner, R
    [J]. INFECTION, 1999, 27 (Suppl 2) : S19 - S23
  • [2] [Anonymous], 2000, M2A7 NCCLS
  • [3] [Anonymous], 2004, HOSP EPIDEMIOLOGY IN
  • [4] Nosocomial infection: hospital infection surveillance and control
    Arya, SC
    Agarwal, N
    Agarwal, S
    George, S
    Singh, K
    [J]. JOURNAL OF HOSPITAL INFECTION, 2004, 58 (03) : 242 - 243
  • [5] BALLOW CH, 1992, DIAGN MICROBIOL I S2, V15, pS375
  • [6] Barrow GI., 1993, COWAN STEELS MANUAL, V3th
  • [7] INFLUENCE OF NOSOCOMIAL INFECTION ON MORTALITY-RATE IN AN INTENSIVE-CARE UNIT
    BUENOCAVANILLAS, A
    DELGADORODRIGUEZ, M
    LOPEZLUQUE, A
    SCHAFFINOCANO, S
    GALVEZVARGAS, R
    [J]. CRITICAL CARE MEDICINE, 1994, 22 (01) : 55 - 60
  • [8] National Nosocomial Infections Surveillance (NNIS) System Report, data summary from January 1992 through June 2004, issued October 2004
    Cardo, D
    Horan, T
    Andrus, M
    Dembinski, M
    Edwards, J
    Peavy, G
    Tolson, J
    Wagner, D
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2004, 32 (08) : 470 - 485
  • [9] Infection control in the ICU
    Eggimann, P
    Pittet, D
    [J]. CHEST, 2001, 120 (06) : 2059 - 2093
  • [10] NATIONAL NOSOCOMIAL INFECTIONS SURVEILLANCE SYSTEM (NNIS) - DESCRIPTION OF SURVEILLANCE METHODS
    EMORI, TG
    CULVER, DH
    HORAN, TC
    JARVIS, WR
    WHITE, JW
    OLSON, DR
    BANERJEE, S
    EDWARDS, JR
    MARTONE, WJ
    GAYNES, RP
    HUGHES, JM
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 1991, 19 (01) : 19 - 35