Low noise YBa2Cu3O7-x SQUID magnetometers operated with additional positive feedback

被引:39
作者
Drung, D
Dantsker, E
Ludwig, F
Koch, H
Kleiner, R
Clarke, J
Krey, S
Reimer, D
David, B
Doessel, O
机构
[1] UNIV CALIF BERKELEY,LAWRENCE BERKELEY LAB,DIV SCI MAT,BERKELEY,CA 94720
[2] UNIV CALIF BERKELEY,DEPT PHYS,BERKELEY,CA
[3] UNIV HAMBURG,INST PHYS APPL,D-20355 HAMBURG,GERMANY
[4] PHILIPS RES LABS,DEPT TECH SYST,D-22335 HAMBURG,GERMANY
关键词
D O I
10.1063/1.116036
中图分类号
O59 [应用物理学];
学科分类号
摘要
Three magnetometers based on de superconducting quantum interference devices (SQUIDs) fabricated from YBa2Cu3O7-x, have been operated in a magnetically shielded room using a flux-locked loop involving additional positive feedback with bias current reversal. Two of these devices, integrated multiloop de SQUIDs with outer diameters of 7 mm, achieved white noise levels of 10 fT/root Hz for bicrystal junctions and 30 fT/root Hz for step-edge junctions. The third magnetometer involved a flux transformer with a 10X10 mm(2) pickup coil connected to a 16-turn input coil which was inductively coupled to a bicrystal SQUID. This device achieved a white noise of 16.2 fT/root Hz. High quality magnetocardiograms were obtained without signal averaging. (C) 1996 American Institute of Physics.
引用
收藏
页码:1856 / 1858
页数:3
相关论文
共 12 条
[1]   TUNNEL JUNCTION DC SQUID - FABRICATION, OPERATION, AND PERFORMANCE [J].
CLARKE, J ;
GOUBAU, WM ;
KETCHEN, MB .
JOURNAL OF LOW TEMPERATURE PHYSICS, 1976, 25 (1-2) :99-144
[2]   LOW-NOISE YBA2CU3O7-X-SRTIO3-YBA2CU3O7-X MULTILAYERS FOR IMPROVED SUPERCONDUCTING MAGNETOMETERS (VOL 66, PG 373, 1995) [J].
DANTSKER, E ;
LUDWIG, F ;
KLEINER, R ;
CLARKE, J ;
TEEPE, M ;
LEE, LP ;
ALFORD, NM ;
BUTTON, T .
APPLIED PHYSICS LETTERS, 1995, 67 (05) :725-726
[3]   A MULTILAYER PROCESS FOR THE FABRICATION OF HTSC FLUX TRANSFORMERS AND SQUIDS [J].
DAVID, BR ;
GRUNDLER, D ;
ECKART, R ;
FANGHANEL, K ;
KRUMME, JP ;
DOORMANN, V ;
DOSSEL, O .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1994, 7 (05) :287-289
[4]   THEORY FOR THE MULTILOOP DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER AND EXPERIMENTAL-VERIFICATION [J].
DRUNG, D ;
KNAPPE, S ;
KOCH, H .
JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) :4088-4098
[5]   LOW-FREQUENCY NOISE IN LOW-T-C MULTILOOP MAGNETOMETERS WITH ADDITIONAL POSITIVE FEEDBACK [J].
DRUNG, D .
APPLIED PHYSICS LETTERS, 1995, 67 (10) :1474-1476
[6]   AN ELECTRONIC SECOND-ORDER GRADIOMETER FOR BIOMAGNETIC APPLICATIONS IN CLINICAL SHIELDED ROOMS [J].
Drung, D. ;
Koch, H. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1993, 3 (01) :2594-2597
[7]   LOW-NOISE HIGH-SPEED DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER WITH SIMPLIFIED FEEDBACK ELECTRONICS [J].
DRUNG, D ;
CANTOR, R ;
PETERS, M ;
SCHEER, HJ ;
KOCH, H .
APPLIED PHYSICS LETTERS, 1990, 57 (04) :406-408
[8]  
DRUNG D, IN PRESS NATO ASI SE
[9]  
ERNE SN, 1981, BIOMAGNETISM, P79
[10]   FLICKER (1/F) NOISE IN TUNNEL JUNCTION DC SQUIDS [J].
KOCH, RH ;
CLARKE, J ;
GOUBAU, WM ;
MARTINIS, JM ;
PEGRUM, CM ;
VANHARLINGEN, DJ .
JOURNAL OF LOW TEMPERATURE PHYSICS, 1983, 51 (1-2) :207-226