Eluent jet interface for combining capillary liquid flows with electron impact mass spectrometry

被引:29
作者
Kientz, CE
Hulst, AG
DeJong, AL
Wils, ERJ
机构
[1] TNO Prins Maurits Laboratory, 2280 AA Rijswijk
关键词
D O I
10.1021/ac950892z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new interface based on an eluent jet in combination with a conventional gas chromatography momentum separator for use with electron impact mass spectrometry is described. The formation of the eluent jet is based on radio frequency inductive heating. The aerosol formation in the; interface is discussed in relation to commercial particle beam (PB) interfaces. The interface is tested in combination with electron impact mass spectrometry using flow injection analysis at now rates in the range of 5-15 mu L/min commonly encountered in microcolumn liquid chromatography. Electron impact spectra at 1-10-ng levels are found to be comparable with reference spectra. In the single-ion mode, 50 pg of caffeine is detectable with a signal-to-noise ratio of 3:1. Contrary to many other PB systems, linear calibration plots are obtained in the tested range of 3-200 ng of caffeine.
引用
收藏
页码:675 / 681
页数:7
相关论文
共 27 条
[1]   QUANTITATION AND LINEARITY FOR PARTICLE-BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
APFFEL, A ;
PERRY, ML .
JOURNAL OF CHROMATOGRAPHY, 1991, 554 (1-2) :103-118
[2]   INVESTIGATION OF ENHANCED ION ABUNDANCES FROM A CARRIER PROCESS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PARTICLE BEAM MASS-SPECTROMETRY [J].
BELLAR, TA ;
BEHYMER, TD ;
BUDDE, WL .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (01) :92-98
[3]   THE MATRIX EFFECT IN PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY AND RELIABLE QUANTIFICATION BY ISOTOPE-DILUTION [J].
BROWN, FR ;
DRAPER, WM .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (09) :515-521
[4]   EVALUATION OR THE PERFORMANCE OF A MICROFLOW RATE LC/MS PARTICLE-BEAM INTERFACE [J].
CAPPIELLO, A ;
FAMIGLINI, G .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :3970-3976
[5]   MICRO FLOW-RATE PARTICLE BEAM INTERFACE FOR CAPILLARY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
CAPPIELLO, A ;
BRUNER, F .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1281-1287
[6]   PARTICLE-BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - INSTRUMENTATION AND APPLICATIONS - A REVIEW [J].
CREASER, CS ;
STYGALL, JW .
ANALYST, 1993, 118 (12) :1467-1480
[7]   ISOTOPE-DILUTION LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY USING A PARTICLE BEAM INTERFACE [J].
DOERGE, DR ;
BURGER, MW ;
BAJIC, S .
ANALYTICAL CHEMISTRY, 1992, 64 (11) :1212-1216
[8]   DROPLET ELECTROSPRAY MASS-SPECTROMETRY [J].
HAGER, DB ;
DOVICHI, NJ ;
KLASSEN, J ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :3944-3949
[9]   MASS-TRANSPORT AND CALIBRATION IN LIQUID-CHROMATOGRAPHY PARTICLE BEAM MASS-SPECTROMETRY [J].
HO, JS ;
BEHYMER, TD ;
BUDDE, WL ;
BELLAR, TA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (06) :662-671
[10]   EVALUATION OF THE PARTICLE-BEAM INTERFACE FOR PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY MASS-SPECTROMETRY WITH PURE AND MODIFIED CO2 [J].