Development of a standard reference material for vitamin D in serum

被引:123
作者
Phinney, Karen W. [1 ]
机构
[1] Natl Inst Stand & Technol, Div Analyt Chem, Chem Sci & Technol Lab, Gaithersburg, MD 20899 USA
关键词
D O I
10.1093/ajcn/88.2.511S
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
The most widely used indicator of vitamin D status is the measurement of 25-hydroxyvitamin D [25(OH)D] in either serum or plasma. Several studies have reported discrepancies between the results of assays used to measure 25(OH)D, however, which calls into question the ability of 25(OH)D assays to reflect accurately the vitamin D status of individuals. The National Institute of Standards and Technology has been working with the National Institutes of Health's Office of Dietary Supplements to develop a standard reference material for circulating vitamin D analysis. This standard reference material will provide a material with stable, well-defined levels of the analytes of interest. Investigators will be able to use the standard reference material to validate new analytic methods as they are developed and to assign values to in-house quality-control materials.
引用
收藏
页码:511S / 512S
页数:2
相关论文
共 6 条
[1]   Assay variation confounds the diagnosis of hypovitaminosis D: A call for standardization [J].
Binkley, N ;
Krueger, D ;
Cowgill, CS ;
Plum, L ;
Lake, E ;
Hansen, KE ;
DeLuca, HF ;
Drezner, MK .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (07) :3152-3157
[2]   How accurate are assays for 25-hydroxyvitamin D? Data from the international vitamin D external quality assessment scheme [J].
Carter, GD ;
Carter, R ;
Jones, J ;
Berry, J .
CLINICAL CHEMISTRY, 2004, 50 (11) :2195-2197
[3]   Issues of methodology, standardization and metabolite recognition for 25-hydroxyvitamin D when comparing the DiaSorin radioimmunoassay and the Nichols Advantage automated chemiluminescence protein-binding assay in hip fracture cases [J].
Glendenning, P ;
Noble, JM ;
Taranto, M ;
Musk, AA ;
McGuiness, M ;
Goldswain, PR ;
Fraser, WD ;
Vasikaran, SD .
ANNALS OF CLINICAL BIOCHEMISTRY, 2003, 40 :546-551
[4]   Editorial: The determination of circulating 25-hydroxyvitamin D: No easy task [J].
Hollis, BW .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (07) :3149-3151
[5]   HPLC method for 25-hydroxyvitamin D measurement: Comparison with contemporary assays [J].
Lensmeyer, Gary L. ;
Wiebe, Donald A. ;
Binkley, Neil ;
Drezner, Marc K. .
CLINICAL CHEMISTRY, 2006, 52 (06) :1120-1126
[6]   C-3 epimers can account for a significant proportion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status [J].
Singh, Ravinder J. ;
Taylor, Robert L. ;
Reddy, G. Satyanarayana ;
Grebe, Stefan K. G. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2006, 91 (08) :3055-3061