Comparison of Qualitative and Quantitative Evaluation of Diffusion-Weighted MRI and Chemical-Shift Imaging in the Differentiation of Benign and Malignant Vertebral Body Fractures

被引:54
作者
Geith, Tobias [1 ]
Schmidt, Gerwin [1 ]
Biffar, Andreas [1 ]
Dietrich, Olaf [1 ]
Duerr, Hans Roland [1 ]
Reiser, Maximilian [1 ]
Baur-Melnyk, Andrea [1 ]
机构
[1] LMU Univ Munich, Inst Clin Radiol, D-81377 Munich, Bavaria, Germany
关键词
chemical-shift imaging; diffusion-weighted imaging; metastatic fracture; musculoskeletal imaging; osteoporotic fracture; spine; vertebral body fractures; PATHOLOGICAL COMPRESSION FRACTURES; FREE PRECESSION SEQUENCE; BONE-MARROW; DIAGNOSTIC-VALUE; IN-PHASE; METASTASES; SPINE; COEFFICIENTS; DISTINCTION; APPEARANCE;
D O I
10.2214/AJR.11.8010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The objective of our study was to compare the diagnostic value of qualitative diffusion-weighted imaging (DWI), quantitative DWI, and chemical-shift imaging in a single prospective cohort of patients with acute osteoporotic and malignant vertebral fractures. SUBJECTS AND METHODS. The study group was composed of patients with 26 osteoporotic vertebral fractures (18 women, eight men; mean age, 69 years; age range, 31 years 6 months to 86 years 2 months) and 20 malignant vertebral fractures (nine women, 11 men; mean age, 63.4 years; age range, 24 years 8 months to 86 years 4 months). T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW reverse fast imaging with steady-state free precession (PSIF) sequence at different delta values was evaluated qualitatively. A DW echo-planar imaging (EPI) sequence and a DW single-shot turbo spin-echo (TSE) sequence at different b values were evaluated qualitatively and quantitatively using the apparent diffusion coefficient. Opposed-phase sequences were used to assess signal intensity qualitatively. The signal loss between in-and opposed-phase images was determined quantitatively. Two-tailed Fisher exact test, Mann-Whitney test, and receiver operating characteristic analysis were performed. Sensitivities, specificities, and accuracies were determined. RESULTS. Qualitative DW-PSIF imaging (delta = 3 ms) showed the best performance for distinguishing between benign and malignant fractures (sensitivity, 100%; specificity, 88.5%; accuracy, 93.5%). Qualitative DW-EPI (b = 50 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.50]) and DW single-shot TSE imaging (b = 100 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.18]; b = 400 s/mm(2) [p = 0.18]; b = 600 s/mm(2) [p = 0.39]) did not indicate significant differences between benign and malignant fractures. DW-EPI using a b value of 500 s/mm(2) (p = 0.01) indicated significant differences between benign and malignant vertebral fractures. Quantitative DW-EPI (p = 0.09) and qualitative opposed-phase imaging (p = 0.06) did not exhibit significant differences, quantitative DW single-shot TSE imaging (p = 0.002) and quantitative chemical-shift imaging (p = 0.01) showed significant differences between benign and malignant fractures. CONCLUSION. The DW-PSIF sequence (delta = 3 ms) had the highest accuracy in differentiating benign from malignant vertebral fractures. Quantitative chemical-shift imaging and quantitative DW single-shot TSE imaging had a lower accuracy than DW-PSIF imaging because of a large overlap. Qualitative assessment of opposed-phase, DW-EPI, and DW single-shot TSE sequences and quantitative assessment of the DW-EPI sequence were not suitable for distinguishing between benign and malignant vertebral fractures.
引用
收藏
页码:1083 / 1092
页数:10
相关论文
共 38 条
[1]
CAN WE DISTINGUISH BETWEEN BENIGN VERSUS MALIGNANT COMPRESSION FRACTURES OF THE SPINE BY MAGNETIC-RESONANCE-IMAGING [J].
AN, HS ;
ANDRESHAK, TG ;
NGUYEN, C ;
WILLIAMS, A ;
DANIELS, D .
SPINE, 1995, 20 (16) :1776-1782
[2]
Diagnostic value of apparent diffusion coefficients to differentiate benign from malignant vertebral bone marrow lesions [J].
Balliu, E. ;
Vilanova, J. C. ;
Pelaez, I. ;
Puig, J. ;
Remollo, S. ;
Barcelo, C. ;
Barcelo, J. ;
Pedraza, S. .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 69 (03) :560-566
[3]
Diffusion-weighted imaging of bone marrow: current status [J].
Baur, A ;
Dietrich, O ;
Reiser, M .
EUROPEAN RADIOLOGY, 2003, 13 (07) :1699-1708
[4]
Differentiation of benign osteoporotic and neoplastic vertebral compression fractures with a diffusion-weighted, steady-state free precession sequence [J].
Baur, A ;
Huber, A ;
Dürr, HR ;
Nikolaou, K ;
Stäbler, A ;
Deimling, M ;
Reiser, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (01) :70-75
[5]
Diffusion-weighted MR imaging of bone marrow:: Differentiation of benign versus pathologic compression fractures [J].
Baur, A ;
Stäbler, A ;
Brüning, R ;
Bartl, R ;
Krödel, A ;
Reiser, M ;
Deimling, M .
RADIOLOGY, 1998, 207 (02) :349-356
[6]
Baur A, 2001, AM J NEURORADIOL, V22, P366
[7]
Baur-Melnyk Andrea, 2009, Cancer Imaging, V9 Spec No A, pS49, DOI 10.1102/1470-7330.2009.9013
[8]
Multiparameter MRI assessment of normal-appearing and diseased vertebral bone marrow [J].
Biffar, Andreas ;
Baur-Melnyk, Andrea ;
Schmidt, Gerwin P. ;
Reiser, Maximilian F. ;
Dietrich, Olaf .
EUROPEAN RADIOLOGY, 2010, 20 (11) :2679-2689
[9]
Castillo M, 2000, AM J NEURORADIOL, V21, P948
[10]
Acute vertebral body compression fractures: discrimination between benign and malignant causes using apparent diffusion coefficients [J].
Chan, JHM ;
Peh, WCG ;
Tsui, EYK ;
Chau, LF ;
Cheung, KK ;
Chan, KB ;
Yuen, MK ;
Wong, ETH ;
Wong, KPC .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (891) :207-214