Stability of insulin lispro in insulin infusion systems

被引:38
作者
Lougheed, WD
Zinman, B
Strack, TR
Janis, LJ
Weymouth, AB
Bernstein, EA
Korbas, AM
Frank, BH
机构
[1] UNIV TORONTO,SAMUEL LUNENFELD RES INST,TORONTO,ON,CANADA
[2] ELI LILLY & CO,TORONTO,ON,CANADA
[3] LILLY RES LABS,INDIANAPOLIS,IN
关键词
D O I
10.2337/diacare.20.7.1061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE -- To test stability of insulin lispro in two insulin infusion systems over 48 h. RESEARCH DESIGN AND METHODS -- We used reverse-phase and size-exclusion high-performance liquid chromatography (HPLC) to determine the purity, potency, and degree of polymerization of U100 insulin lispro (Humalog) after 24- and 48-h pump cycles conducted at 37 degrees in five Disetronic H-TRON V100 and five MiniMed 504 pumps. Pumps were set to deliver a basal rate of 0.5 U/h and 6-U boluses at t = 0, 4, 8, 24, 24.5, 28.5, 32.5, and 48 h during each cycle. The effluent was collected into l-ml vials, pooled at 24 or 48 h, and stored at 4 degrees C until assay After each 48-h run period of insulin delivery, assays for potency, polymer and purity were performed on the pooled samples from each individual cycle. m-cresol content and the pooled reservoir content were assayed in the 48-h pooled samples. RESULTS -- Insulin lispro retained full HPLC potency (Delta less than or equal to 4%) at 48 h, with no degradation of insulin lispro to des-amidoinsulin forms (24 or 48 h). No increase in pumped insulin polymer concentration was observed following 24 h of pump flow Nonsignificant increases of less than or equal to 0.09% (Disetronic) and less than or equal to 0.15% (MiniMed) from initial concentrations of 0.18% (polymer divided by total insulin) were detected in three of five pump cycles at 48 h when compared with 37 degrees C paired controls. Nonsignificant decreases (<5 and 10%, Disetronic and MiniMed, respectively) of m-cresol content occurred in both systems following 48 h storage in each device, but sterility was not compromised by this decrease (initial m-cresol concentration, 3.15 mg/ml). Pump performance was without mechanical or electrical fault throughout the study. Basal and bolus insulin delivery was evaluated three times daily and remained as expected. Occlusion of catheters by insulin precipitation did not occur, and no change in pH was observed following delivery. CONCLUSIONS -- We conclude that insulin lispro is suitable for prolonged infusion in these two medical devices when syringes and catheters are replaced at 48-h intervals.
引用
收藏
页码:1061 / 1065
页数:5
相关论文
共 31 条
[1]   Reduction of postprandial hyperglycemia and frequency of hypoglycemia in IDDM patients on insulin-analog treatment [J].
Anderson, JH ;
Brunelle, RL ;
Koivisto, VA ;
Pfutzner, A ;
Trautmann, ME ;
Vignati, L ;
DiMarchi, R ;
Bowen, KM ;
Cameron, DP ;
Nankervis, AJ ;
Roberts, AP ;
Zimmet, P ;
Borkenstein, MH ;
Schernthaner, G ;
Waldhausl, WK ;
DeLeeuw, IH ;
Fery, F ;
Scheen, A ;
Somers, G ;
Fettes, IM ;
Tildesley, HD ;
Toth, EL ;
Viikari, J ;
Altman, JJ ;
Bougneres, PF ;
Drouin, P ;
Fossati, P ;
Guillausseau, PJ ;
Marechaud, E ;
Riou, JP ;
Selam, JL ;
Vialettes, PB ;
Beyer, J ;
Federlin, K ;
Fussganger, RD ;
Gries, FA ;
Jastram, HU ;
Koop, I ;
Landgraf, R ;
Rosak, C ;
Schatz, H ;
SchulzeSchleppinghoff, B ;
Seif, FJ ;
Stoeckmann, F ;
Karasik, A ;
Weitzman, S ;
Andreani, D ;
Bompiani, G ;
Crepaldi, G ;
Giorgino, R .
DIABETES, 1997, 46 (02) :265-270
[2]  
BRANGE J, 1983, ACTA MED SCAND S, V671, P135
[3]   SOME REACTIONS OF INSULIN AT NONPOLAR SURFACES [J].
BROWNE, M ;
CECIL, R ;
MILLER, JC .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1973, 33 (02) :233-240
[4]  
CARPENTER FH, 1962, J BIOL CHEM, V237, P404
[5]   INTERACTION BETWEEN PLASTIC CATHETER TUBINGS AND REGULAR INSULIN PREPARATIONS USED FOR CONTINUOUS SUBCUTANEOUS INSULIN-INFUSION THERAPY [J].
CHANTELAU, E ;
LANGE, G ;
GASTHAUS, M ;
BOXBERGER, M ;
BERGER, M .
DIABETES CARE, 1987, 10 (03) :348-351
[6]   ACUTE CUTANEOUS COMPLICATIONS AND CATHETER NEEDLE COLONIZATION DURING INSULIN-PUMP TREATMENT [J].
CHANTELAU, E ;
LANGE, G ;
SONNENBERG, GE ;
BERGER, M .
DIABETES CARE, 1987, 10 (04) :478-482
[7]   ROLE OF C-TERMINAL B-CHAIN RESIDUES IN INSULIN ASSEMBLY - THE STRUCTURE OF HEXAMERIC LYS(B28)PRO(B29)-HUMAN INSULIN [J].
CISZAK, E ;
BEALS, JM ;
FRANK, BH ;
BAKER, JC ;
CARTER, ND ;
SMITH, GD .
STRUCTURE, 1995, 3 (06) :615-622
[8]  
*COUNC EUR, 1997, EUR PHARM
[9]   PREPARATION OF AN INSULIN WITH IMPROVED PHARMACOKINETICS RELATIVE TO HUMAN INSULIN THROUGH CONSIDERATION OF STRUCTURAL HOMOLOGY WITH INSULIN-LIKE GROWTH-FACTOR-I [J].
DIMARCHI, RD ;
CHANCE, RE ;
LONG, HB ;
SHIELDS, JE ;
SLIKER, LJ .
HORMONE RESEARCH, 1994, 41 :93-96
[10]  
FREEMAN DJ, 1983, LANCET, V1, P828