Neither the accuracy nor the precision of thermal dilution cardiac output measurements is altered by acute tricuspid regurgitation in pigs

被引:21
作者
Buffington, CW
Nystrom, EUM
机构
[1] Univ Pittsburgh, Dept Anesthesiol, Pittsburgh, PA 15261 USA
[2] Creighton Univ, Dept Anesthesiol, Omaha, NE 68178 USA
关键词
D O I
10.1213/01.ANE.0000105923.09732.93
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Whether measurement of cardiac output using the thermal dilution technique (TDCO) is valid in the presence of tricuspid regurgitation (TR) is controversial. We assessed the accuracy and precision of the technique in pigs by comparison with data from an electromagnetic flowmeter on the aorta (EMCO). TR was created with sutures that immobilized the free-wall leaflets of the tricuspid valve, and cardiac output was adjusted with dobutamine to give values comparable to control measurements. TR reduced forward stroke volume from 17.2 to 12.6 mL/beat and caused the right atrium to dilate and pulse in synchrony with the right ventricle. Acute TR did not affect the linear regression relation between TDCO and EMCO and did not alter the correlation coefficient (r = 0.94 during both control and TR). These data demonstrate that acute TR does not affect the accuracy or precision of TDCO in pigs.
引用
收藏
页码:884 / 890
页数:7
相关论文
共 17 条
[1]   Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution [J].
Balik, M ;
Pachl, J ;
Hendl, J .
INTENSIVE CARE MEDICINE, 2002, 28 (08) :1117-1121
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   VALIDITY OF CARDIAC-OUTPUT MEASUREMENT BY THE THERMODILUTION METHOD IN THE PRESENCE OF ACUTE TRICUSPID REGURGITATION [J].
BOERBOOM, LE ;
KINNEY, TE ;
OLINGER, GN ;
HOFFMANN, RG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 106 (04) :636-642
[4]   UNDERESTIMATION OF CARDIAC-OUTPUT BY THERMODILUTION IN PATIENTS WITH TRICUSPID REGURGITATION [J].
CIGARROA, RG ;
LANGE, RA ;
WILLIAMS, RH ;
BEDOTTO, JB ;
HILLIS, LD .
AMERICAN JOURNAL OF MEDICINE, 1989, 86 (04) :417-420
[5]   ANALYSIS OF ERRORS IN MEASUREMENT OF CARDIAC-OUTPUT BY SIMULTANEOUS DYE AND THERMAL DILUTION IN CARDIOTHORACIC SURGICAL PATIENTS [J].
FISCHER, AP ;
BENIS, AM ;
JURADO, RA ;
SEELY, E ;
TEIRSTEIN, P ;
LITWAK, RS .
CARDIOVASCULAR RESEARCH, 1978, 12 (03) :190-199
[6]   CURRENT CONCEPTS - CARDIOPULMONARY MONITORING OF CRITICALLY ILL PATIENTS .2. [J].
GOLDENHEIM, PD ;
KAZEMI, H .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 311 (12) :776-780
[7]   EFFECT OF TRICUSPID REGURGITATION ON THE RELIABILITY OF THE THERMODILUTION CARDIAC-OUTPUT TECHNIQUE IN CONGESTIVE HEART-FAILURE [J].
HAMILTON, MA ;
STEVENSON, LW ;
WOO, M ;
CHILD, JS ;
TILLISCH, JH .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (14) :945-948
[8]   Flow dependency of error in thermodilution measurement of cardiac output during acute tricuspid regurgitation [J].
Heerdt, PM ;
Blessios, GA ;
Beach, ML ;
Hogue, CW .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (02) :183-187
[9]   INACCURACY OF CARDIAC-OUTPUT BY THERMODILUTION DURING ACUTE TRICUSPID REGURGITATION [J].
HEERDT, PM ;
POND, CG ;
BLESSIOS, GA ;
ROSENBLOOM, M .
ANNALS OF THORACIC SURGERY, 1992, 53 (04) :706-708
[10]   Determination of cardiac output by the Fick method, thermodilution, and acetylene rebreathing in pulmonary hypertension [J].
Hoeper, MM ;
Maier, R ;
Tongers, J ;
Niedermeyer, J ;
Hohlfeld, JM ;
Hamm, M ;
Fabel, H .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (02) :535-541