Spatiotemporal evaluation of human colon motility using three-axis fluxgates and magnetic markers

被引:9
作者
Córdova-Fraga, T
Carneiro, AAO
de Araujo, DB
Oliveira, RB
Sosa, M [1 ]
Baffa, O
机构
[1] Univ Sao Paulo, Dept Fis & Matemat, FFCLRP, Sao Paulo, Brazil
[2] Univ Guanajuato, Inst Fis, Guanajuato, Mexico
[3] Univ Sao Paulo, Fac Med Ribeirao Preto, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
magnetic marker; contractile activity frequencies; colon motility;
D O I
10.1007/BF02430947
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
An alternative method to study the mechanical activity of the human colon in fasting and postprandial states is presented. The method is based on measurements of the magnetic fields produced by a magnetic marker, a small cylindrical NdBFe magnet, when it was ingested by the subjects. A portable magnetic probe, consisting of two digital three-axis fluxgate magnetometers, arranged in a first-order electronic gradiometer, was implemented for this research. Measurements were taken in 16 healthy male subjects. Contractile activity frequency measurements were taken along the colon length, including the ascending, transverse and descending sections, as well as the rectal sigmoidal section. Values for the contractile activity frequency of 2-5 cycles min(-1) were measured. The set-up is simple, low-cost and suitable for use in an unshielded environment.
引用
收藏
页码:712 / 715
页数:4
相关论文
共 18 条
[1]
GASTROINTESTINAL AND COLONIC SEGMENTAL TRANSIT-TIME EVALUATED BY A SINGLE ABDOMINAL X-RAY IN HEALTHY-SUBJECTS AND CONSTIPATED PATIENTS [J].
ABRAHAMSSON, H ;
ANTOV, S ;
BOSAEUS, I .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1988, 23 :72-80
[2]
MEASUREMENT OF SEGMENTAL TRANSIT THROUGH THE GUT IN MAN - A NOVEL-APPROACH BY THE BIOMAGNETIC METHOD [J].
BASILE, M ;
NERI, M ;
CARRIERO, A ;
CASCIARDI, S ;
COMANI, S ;
DELGRATTA, C ;
DIDONATO, L ;
DILUZIO, S ;
MACRI, MA ;
PASQUARELLI, A ;
PIZZELLA, V ;
ROMANI, GL .
DIGESTIVE DISEASES AND SCIENCES, 1992, 37 (10) :1537-1543
[3]
Carneiro A. A. O., 2000, REV BRAS ENSINO FIS, V22, P324
[4]
Study of stomach motility using the relaxation of magnetic tracers [J].
Carneiro, AA ;
Baffa, O ;
Oliveira, RB .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (07) :1691-1697
[6]
COWLES VE, 1995, AM J PHYSIOL-GASTR L, V32, P408
[7]
Study of the magnetic content movement present, in the large intestine [J].
Ferreira, A ;
Carneiro, AAO ;
Moraes, ER ;
Oliveira, RB ;
Baffa, O .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 283 (01) :16-21
[8]
Gastric emptying of solids measured by means of magnetised iron oxide powder [J].
Forsman, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (01) :2-6
[9]
Intragastric movement assessment by measuring magnetic field decay of magnetised tracer particles in a solid meal [J].
Forsman, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (02) :169-174
[10]
AN AC-BIOSUSCEPTOMETER TO STUDY GASTRIC-EMPTYING [J].
MIRANDA, JR ;
BAFFA, O ;
DEOLIVEIRA, RB ;
MATSUDA, NM .
MEDICAL PHYSICS, 1992, 19 (02) :445-448