Functionalised electrode array for the detection of nitric oxide released by endothelial cells using different NO-sensing chemistries

被引:35
作者
Oni, J
Pailleret, A
Isik, S
Diab, N
Radtke, I
Blöchl, A
Jackson, M
Bedioui, F
Schuhmann, W
机构
[1] Ruhr Univ Bochum, Lehrstuhl Mol Neurobiochem, D-44780 Bochum, Germany
[2] Ecole Natl Super Chim Paris, Lab Electrochim & Chim Analyt, UMR CNRS ENSCP 7575, F-75231 Paris 05, France
[3] Cent Res Labs Ltd, Hayes, Middx, England
关键词
nitric oxide; electrodes array; electrocatalysis; chemically modified electrodes; HUVEC;
D O I
10.1007/s00216-004-2512-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In a preliminary study aimed at developing strategies for the simultaneous detection of various biologically important molecules, a procedure is described that allows the electrochemical detection of nitric oxide (NO) released by a population of human umbilical vein endothelial cells (HUVEC) by using an array of electrodes comprising three individually addressable electrodes. Each electrode in the array was modified with a different NO-sensitive electrocatalyst, thereby demonstrating the possibility of modifying the individual electrodes in an array with different sensing chemistries. This study opens a doorway to the development of arrays of electrodes for the simultaneous detection of multiple analytes in a complex environment by suitably tailoring the sensitivity and selectivity of each electrode in the array to a specific analyte in the test medium.
引用
收藏
页码:1594 / 1600
页数:7
相关论文
共 24 条
[1]  
ADDLER AD, 1970, J INORG NUCL CHEM, V32, P2443
[2]   Design and characterization of chemically modified electrodes with iron(III) porphyrinic-based polymers: Study of their reactivity toward nitrites and nitric oxide in aqueous solution [J].
Bedioui, F ;
Trevin, S ;
Albin, V ;
Villegas, MGG ;
Devynck, J .
ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) :177-185
[3]   Elaboration and use of nickel planar macrocyclic complex-based sensors for the direct electrochemical measurement of nitric oxide in biological media [J].
Bedioui, F ;
Trevin, S ;
Devynck, J ;
Lantoine, F ;
Brunet, A ;
Devynck, MA .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (03) :205-212
[4]   Electrochemical nitric oxide sensors for biological samples - Principle, selected examples and applications [J].
Bedioui, F ;
Villeneuve, N .
ELECTROANALYSIS, 2003, 15 (01) :5-18
[5]   Electrochemical sensing of nitric oxide for biological systems: methodological approach and new insights in examining interfering compounds [J].
Brunet, A ;
Pailleret, A ;
Devynck, MA ;
Devynck, J ;
Bedioui, F .
TALANTA, 2003, 61 (01) :53-59
[6]   Electrocatalytic activity of substituted metallophthalocyanines adsorbed on vitreous carbon electrode for nitric oxide oxidation [J].
Caro, CA ;
Zagal, JH ;
Bedioui, F .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2003, 150 (02) :E95-E103
[7]   Pyrrole functionalised metalloporphyrins as electrocatalysts for the oxidation of nitric oxide [J].
Diab, N ;
Oni, J ;
Schulte, A ;
Radtke, I ;
Blöchl, A ;
Schuhmann, W .
TALANTA, 2003, 61 (01) :43-51
[8]   Electropolymerized manganese porphyrin/polypyrrole films as catalytic surfaces for the oxidation of nitric oxide [J].
Diab, N ;
Schuhmann, W .
ELECTROCHIMICA ACTA, 2001, 47 (1-2) :265-273
[9]  
Fiaccabrino GC, 1998, ELECTROANAL, V10, P217, DOI 10.1002/(SICI)1521-4109(199804)10:4<217::AID-ELAN217>3.0.CO
[10]  