Receiver operating characteristic study of image preprocessing for teleradiology and digital workstations

被引:9
作者
Bolle, SR
Sund, T
Stormer, J
机构
[1] TELENOR R&D,N-9005 TROMSO,NORWAY
[2] UNIV TROMSO HOSP,DEPT RADIOL,TROMSO,NORWAY
关键词
teleradiology; image processing; histogram equalization; radiology; receiver operating characteristic (ROC) analysis;
D O I
10.1007/BF03168837
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate whether digitized analog images displayed on a digital workstation can be improved by using a preprocessing algorithm, and if so, whether the quality of the resulting images can reach that of the original films, The material contained 120 difficult cases (about 50% with selected pathology), Four radiologists each evaluated half of the randomly ordered cases with the digital workstation and half of the cases with the original radiographs. The data were compared with a previous similar study, where the workstation had no option for preprocessed images. Preprocessed digital images were clearly superior to digital images without preprocessing, although for those of the highest diagnostic difficulty they were inferior to the original films, The preprocessing algorithm has improved the diagnostic quality of the digital workstation. There is room yet for improvement compared to plain films, although the current setup may be sufficient in some settings. Copyright (C) 1997 by W.B. Saunders Company.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 9 条
[1]   INTERPRETATION OF ROENTGENOGRAMS VIA INTERACTIVE TELEVISION [J].
ANDRUS, WS ;
DREYFUSS, JR ;
JAFFER, F ;
BIRD, KT .
RADIOLOGY, 1975, 116 (01) :25-31
[2]  
CURTIS DJ, 1993, RADIOLOGY, V149, P415
[3]  
KIRKWOOD BR, 1988, ESSENTIALS MED STATI, P87
[4]   ADAPTIVE HISTOGRAM EQUALIZATION AND ITS VARIATIONS [J].
PIZER, SM ;
AMBURN, EP ;
AUSTIN, JD ;
CROMARTIE, R ;
GESELOWITZ, A ;
GREER, T ;
TERHAARROMENY, B ;
ZIMMERMAN, JB ;
ZUIDERVELD, K .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1987, 39 (03) :355-368
[5]  
RAZAVI M, 1991, MED IMAGING, V5, P24
[6]   SUBTLE ORTHOPEDIC FRACTURES - TELERADIOLOGY WORKSTATION VERSUS FILM INTERPRETATION [J].
SCOTT, WW ;
ROSENBAUM, JE ;
ACKERMAN, SJ ;
REICHLE, RL ;
MAGID, D ;
WELLER, JC ;
GITLIN, JN .
RADIOLOGY, 1993, 187 (03) :811-815
[7]   INTERPRETATION OF EMERGENCY DEPARTMENT RADIOGRAPHS BY RADIOLOGISTS AND EMERGENCY-MEDICINE PHYSICIANS - TELERADIOLOGY WORKSTATION VERSUS RADIOGRAPH READINGS [J].
SCOTT, WW ;
BLUEMKE, DA ;
MYSKO, WK ;
WELLER, GER ;
KELEN, GD ;
REICHLE, RL ;
WELLER, JC ;
GITLIN, JN .
RADIOLOGY, 1995, 195 (01) :223-229
[8]   THE CLINICAL USEFULNESS OF TELERADIOLOGY OF NEONATES - EXPANDED SERVICES WITHOUT EXPANDED STAFF [J].
SLOVIS, TL ;
GUZZARDODOBSON, PR .
PEDIATRIC RADIOLOGY, 1991, 21 (05) :333-335
[9]  
Stormer J, 1997, ACTA RADIOL, V38, P176