Effectiveness of autologous fibrin sealant in experimental lung surgery

被引:4
作者
Kjaergard, HK [1 ]
Axelsen, P [1 ]
机构
[1] UNIV COPENHAGEN,PANUM INST,INST EXPTL RES SURG,DK-2200 COPENHAGEN,DENMARK
关键词
autologous fibrin tissue adhesive; biocompatibility; ethanol precipitation; histology; pulmonary air leak;
D O I
10.1159/000129454
中图分类号
R61 [外科手术学];
学科分类号
摘要
A controlled study was performed to evaluate the effectiveness and biocompatibility of ethanol-prepared fibrin sealant for closure of an experimental pulmonary air leak in pigs. The sealant was based on co-administration of fibrinogen concentrate prepared from plasma by ethanol precipitation and thrombin solution. Standardized wedge resections were created bilaterally in the lungs of 5 pigs and sutured on both sides. The lungs were randomized for treatment with fibrin glue or as a control no sealant. Chest tubes were inserted and the volume of leaked air measured at regular intervals for 2 h after sealant application. In 3 pigs, survival studies were performed to assess the persistence and biocompatibility of the glue. The sealant, prepared either from human plasma or autologous pig plasma, was instilled onto the intact pleura through a thoracoscope. Histological examination of the clots was performed after 3, 7 and 21 days. The mean air leak from the fibrin-sealed lungs was 16 ml/min versus 213 ml/min from the control lungs. The reduction in air leak averaged 92% (95% confidence interval, 74-99%). Infiltration with cells was seen early, and fibroblasts were proliferating after 7 days. At 21 days, the clots were organized and partly resorbed. No differences were seen between the cellular reactions to human or porcine fibrin sealant. In conclusion, air leak after experimental lung surgery was significantly reduced by the use of fibrin glue prepared from plasma. The fibrin sealant appeared to be biocompatible and to function as a scaffold for cell growth. The glue is suitable for autologous use in humans.
引用
收藏
页码:162 / 166
页数:5
相关论文
共 11 条
[1]
FIBRIN SEAL - AN ALTERNATIVE TO SUTURE REPAIR IN EXPERIMENTAL PULMONARY SURGERY [J].
BERGSLAND, J ;
KALMBACH, T ;
BALU, D ;
FELDMAN, MJ ;
CARUANA, JA ;
GAGE, AA .
JOURNAL OF SURGICAL RESEARCH, 1986, 40 (04) :340-345
[2]
VIDEO-ASSISTED THORACIC-SURGERY STUDY-GROUP DATA [J].
HAZELRIGG, SR ;
NUNCHUCK, SK ;
LOCICERO, J .
ANNALS OF THORACIC SURGERY, 1993, 56 (05) :1039-1044
[3]
Hile J., 1978, FDA DRUG BULL, V8, P15
[4]
COMPLICATIONS OF THORACOSCOPY [J].
KAISER, LR ;
BAVARIA, JE .
ANNALS OF THORACIC SURGERY, 1993, 56 (03) :796-798
[5]
AUTOLOGOUS FIBRIN GLUE - PREPARATION AND CLINICAL USE IN THORACIC-SURGERY [J].
KJAERGARD, HK ;
WEISFOGH, US ;
SORENSEN, H ;
THIIS, J ;
RYGG, I .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (01) :52-54
[6]
PREPARATION OF AUTOLOGOUS FIBRIN GLUE FROM PERICARDIAL BLOOD [J].
KJAERGARD, HK ;
WEISFOGH, US ;
THIIS, JJ .
ANNALS OF THORACIC SURGERY, 1993, 55 (02) :543-544
[7]
IMPORTANT FACTORS INFLUENCING THE STRENGTH OF AUTOLOGOUS FIBRIN GLUE - THE FIBRIN CONCENTRATION AND REACTION-TIME - COMPARISON OF STRENGTH WITH COMMERCIAL FIBRIN GLUE [J].
KJAERGARD, HK ;
WEISFOGH, US .
EUROPEAN SURGICAL RESEARCH, 1994, 26 (05) :273-276
[8]
THE EFFECTIVENESS OF FIBRIN GLUE SEALANT FOR REDUCING EXPERIMENTAL PULMONARY AIR LEAK [J].
MCCARTHY, PM ;
TRASTEK, VF ;
BELL, DG ;
BUTTERMANN, GR ;
PIEHLER, JM ;
PAYNE, WS ;
WEILAND, LH ;
PAIROLERO, PC .
ANNALS OF THORACIC SURGERY, 1988, 45 (02) :203-205
[9]
CLOSURE OF LUNG LEAKS BY FIBRIN GLUING - EXPERIMENTAL INVESTIGATIONS AND CLINICAL-EXPERIENCE [J].
TURK, R ;
WEIDRINGER, JW ;
HARTEL, W ;
BLUMEL, G .
THORACIC AND CARDIOVASCULAR SURGEON, 1983, 31 (03) :185-186