Clinical utility of bilateral whole-breast US in the evaluation of women with dense breast tissue

被引:290
作者
Kaplan, SS [1 ]
机构
[1] Strax Inst, Lauderhill, FL 33351 USA
关键词
breast; parenchymal pattern; US; breast neoplasms; diagnosis; breast radiography; quality assurance; cancer screening;
D O I
10.1148/radiol.2213010364
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the clinical utility of bilateral whole-breast ultrasonography (US) as an adjunct examination to mammography in asymptomatic women with dense (Breast Imaging Reporting and Data System [BI-RADS] density category 3 or 4) breast tissue. MATERIALS AND METHODS: Between July 1998 and April 2000, 1,862 patients with negative findings at clinical examinations, negative mammographic results, and breast tissue with BI-RADS category 3 or 4 density were evaluated with bilateral whole-breast US for occult cystic and solid masses, areas of architectural distortion, and acoustic shadowing. Suggestive findings were compared with tissue diagnoses from US-guided core biopsy specimens. US was initially performed by a US or a mammography technologist. The average time to perform the examination was approximately 10 minutes. Abnormal findings were corroborated by a fellowship-trained breast-imaging radiologist. RESULTS: In the 1,862 women examined with bilateral whole-breast US, 57 biopsies were recommended in 56 patients; follow-up data were available in 51 of the 56 patients. Six breast cancers were detected (cancer detection rate, 0.3%). CONCLUSION: Bilateral whole-breast US, when performed in patients with dense (BI-RADS category 3 or 4 density) breast tissue, is useful in detecting breast cancer not discovered with mammography or clinical breast examination. The 0.3% cancer detection rate compares favorably with that of screening mammography and with that in previously published studies involving bilateral whole-breast US.
引用
收藏
页码:641 / 649
页数:9
相关论文
共 20 条
[1]   AUTOMATED AND HAND-HELD BREAST US - EFFECT ON PATIENT-MANAGEMENT [J].
BASSETT, LW ;
KIMMESMITH, C ;
SUTHERLAND, LK ;
GOLD, RH ;
SARTI, D ;
KING, W .
RADIOLOGY, 1987, 165 (01) :103-108
[2]   BREAST SONOGRAPHY [J].
BASSETT, LW ;
KIMMESMITH, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (03) :449-455
[3]   Multicentric and multifocal cancer: Whole-breast US in preoperative evaluation [J].
Berg, WA ;
Gilbreath, PL .
RADIOLOGY, 2000, 214 (01) :59-66
[4]   Incidental findings on sonography of the breast:: Clinical significance and diagnostic workup [J].
Buchberger, W ;
DeKoekkoek-Doll, P ;
Springer, P ;
Obrist, P ;
Dünser, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (04) :921-927
[5]   DETECTION OF BREAST-CARCINOMA - COMPARISON OF AUTOMATED WATER-PATH WHOLE-BREAST SONOGRAPHY, MAMMOGRAPHY, AND PHYSICAL-EXAMINATION [J].
EGAN, RL ;
EGAN, KL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (03) :493-497
[6]   AUTOMATED WATER-PATH FULL-BREAST SONOGRAPHY - CORRELATION WITH HISTOLOGY OF 176 SOLID LESIONS [J].
EGAN, RL ;
EGAN, KL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (03) :499-507
[7]  
FORNAGE BD, 1992, RADIOL CLIN N AM, V30, P167
[8]   THE SELECTED USE OF ULTRASOUND MAMMOGRAPHY TO IMPROVE DIAGNOSTIC-ACCURACY IN CARCINOMA OF THE BREAST [J].
FRAZIER, TG ;
MURPHY, JT .
JOURNAL OF SURGICAL ONCOLOGY, 1985, 29 (04) :231-232
[9]  
GORDON PB, 1995, CANCER, V76, P626, DOI 10.1002/1097-0142(19950815)76:4<626::AID-CNCR2820760413>3.0.CO
[10]  
2-Z