Differences in PM10 concentrations measured by β-gauge monitor and hi-vol sampler

被引:44
作者
Chang, CT
Tsai, CJ [1 ]
Lee, CT
Chang, SY
Cheng, MT
Chein, HM
机构
[1] Natl Chiao Tung Univ, Inst Environm Engn, Hsinchu, Taiwan
[2] Natl Cent Univ, Inst Environm Engn, Chungli 32054, Taiwan
[3] Natl Chunghsing Univ, Inst Environm Engn, Taichung 40227, Taiwan
[4] Ind Technol Res Inst, Hsinchu, Taiwan
关键词
beta-gauge; water content; PM10; relative humidity;
D O I
10.1016/S1352-2310(01)00369-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper. differences between the 24-h average PM10 concentrations of Wedding beta -gauge monitor and Andersen or Wedding hi-vol sampler were studied. When the deliquescent point is not exceeded, PM10 concentrations of the beta -gauge are close to those of the manual samplers. The ratio of beta -gauge PM10 to Andersen PM10 and Wedding PM10 is 1.08 +/-0.06 and 1.09 +/-0.12, respectively. However, when the deliquescent point is exceeded, water absorption by the inorganics of aerosols leads to higher PM10 concentrations of the beta -gauge compared to those of the manual sampler. The ratio of beta -gauge PM10 to Andersen PM10 and Wedding PM10 is 1.21 +/-0.22 and 1.27 +/-0.15, respectively. However., due to evaporation of water from the aerosols collected on the filter tape of the beta -gauge, differences in PM10 concentrations are much less than theoretically calculated. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:5741 / 5748
页数:8
相关论文
共 19 条