Simultaneous detection of hepatitis c virus antigen and antibodies in dried blood spots

被引:32
作者
Brandao, C. P. U. [1 ]
Marques, B. L. C. [2 ]
Marques, V. A. [2 ]
Villela-Nogueira, C. A. [3 ]
Do O, K. M. R. [4 ]
de Paula, M. T. [1 ]
Lewis-Ximenez, L. L. [2 ]
Lampe, E. [2 ]
Sa Ferreira, J. A. [5 ]
Villar, L. M. [2 ]
机构
[1] Fed Hosp Servers State Rio de Janeiro, Rio De Janeiro, Brazil
[2] Fiocruz MS, Inst Oswaldo Cruz, Lab Viral Hepatitis, BR-21045900 Rio De Janeiro, RJ, Brazil
[3] Univ Fed Rio de Janeiro, Clementino Fraga Filho Univ Hosp, Hepatol Div, BR-21941 Rio De Janeiro, RJ, Brazil
[4] Unimed Hosp, Petropolis, RJ, Brazil
[5] Fiocruz MS, Immunobiol Technol Inst Bio Manguinhos, BR-21045900 Rio De Janeiro, RJ, Brazil
关键词
Hepatitis C virus; Dried blood spot; Enzyme immunoassay; HCV AgAb; CORE ANTIGEN; SAMPLES; RNA;
D O I
10.1016/j.jcv.2013.02.014
中图分类号
Q93 [微生物学];
学科分类号
071005 [微生物学];
摘要
Background: Enzyme immunoassays (EIA) designed to detect hepatitis C virus (HCV) core antigen and anti-HCV antibodies (HCV AgAb) simultaneously can improve the early detection of HCV infection when molecular diagnostic methods are not widely available. Objectives: To evaluate the suitability of dried blood spot (DBS) samples for detecting HCV AgAb using commercial EIAs. Study design: Paired serum and DBS samples were assayed using two commercial EIAs for HCV AgAb (Monolisa (TM) HCV AgAb ULTRA and Murex HCV AgAb). Manufacturer's recommendations were followed for sera while sample volume, incubation time and cut-off (CO) determination were evaluated for the DBS samples. The values of sensitivity, specificity, inter-rater agreement, detection limit, assay precision and stability of DBS samples at different conditions (22-26 degrees C, 2-8 degrees C and -20 degrees C) were determined. Results: It was necessary to increase the DBS sample volume fourfold compared to the sera samples to approximate the DBS Optical Density (OD) values to the sera OD values. Using ROC curve to recalculate CO values for the DBS samples, sensitivity was 97.5% for both EIAs, while the specificity was 99.71% for Monolisa (TM) HCV AgAb ULTRA and 95.95% for Murex HCV AgAb. Accurate testing results were obtained with DBS samples for 60 days at all conditions evaluated; storage at -20 degrees C resulted in low OD variation. Both EIAs demonstrated the same limit of detection among DBS samples [ estimated viral load of 3.1 International Units per millilitre (IU/mL)] and low OD value variability in repetitivity and reproducibility studies. Conclusion: DBS samples can be used for the detection of HCV AgAb by EIA as they present comparable performance characteristics and excellent stability among various storage conditions. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:98 / 102
页数:5
相关论文
共 23 条
[1]
Hepatitis C virus RNA in dried serum spotted onto filter paper is stable at room temperature [J].
Abe, K ;
Konomi, N .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (10) :3070-3072
[2]
Capillary whole blood measurement of islet autoantibodies [J].
Bazzigaluppi, E ;
Bonfanti, R ;
Bingley, PJ ;
Bosi, E ;
Bonifacio, E .
DIABETES CARE, 1999, 22 (02) :275-279
[3]
Brasil. Ministerio da Saude. Secretaria de Vigilancia em Saude. Departamento de DST, 2011, B EP HEP VIR, V1
[4]
Novel Evolved Immunoglobulin (Ig)-Binding Molecules Enhance the Detection of IgM against Hepatitis C Virus [J].
Cao, Jie ;
Chen, Qiuli ;
Zhang, Huaqun ;
Qi, Peipei ;
Liu, Chao ;
Yang, Xufang ;
Wang, Niansong ;
Qian, Baohua ;
Wang, Jinhong ;
Jiang, Shaohua ;
Yang, Hua ;
Sun, Shuhan ;
Pan, Wei .
PLOS ONE, 2011, 6 (04)
[5]
Clinical and Laboratory Standards Institute (CLSI), 2004, APPR GUID EP A2 EV P
[6]
Commercial enzyme immunoassay adapted for the detection of antibodies to hepatitis C virus in dried blood spots [J].
Croom, HA ;
Richards, KM ;
Best, SJ ;
Francis, BH ;
Johnson, EIM ;
Dax, EM ;
Wilson, KM .
JOURNAL OF CLINICAL VIROLOGY, 2006, 36 (01) :68-71
[7]
Crowther J, 2001, ELISA GUIDEBOOK METH
[8]
Is an assay for simultaneous detection of hepatitis C virus core antigen and antibody a valuable alternative to nucleic acid testing? [J].
Laperche, S ;
Elghouzzi, MH ;
Morel, P ;
Asso-Bonnet, M ;
Le Marrec, N ;
Girault, A ;
Servant-Delmas, A ;
Bouchardeau, F ;
Deschaseaux, M ;
Piquet, Y .
TRANSFUSION, 2005, 45 (12) :1965-1972
[9]
Dried blood spot samples: Optimization of commercial EIAs for hepatitis C antibody detection and stability under different storage conditions [J].
Marques, B. L. C. ;
Brandao, C. U. ;
Silva, E. F. ;
Marques, V. A. ;
Villela-Nogueira, C. A. ;
Do O, K. M. R. ;
de Paula, M. T. ;
Lewis-Ximenez, L. L. ;
Lampe, E. ;
Villar, L. M. .
JOURNAL OF MEDICAL VIROLOGY, 2012, 84 (10) :1600-1607
[10]
Hepatitis C antibody detection in dried blood spots [J].
McCarron, B ;
Fox, R ;
Wilson, K ;
Cameron, S ;
McMenamin, J ;
McGregor, G ;
Pithie, A ;
Goldberg, D .
JOURNAL OF VIRAL HEPATITIS, 1999, 6 (06) :453-456