Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)

被引:332
作者
Breuer, FA [1 ]
Blaimer, M [1 ]
Mueller, MF [1 ]
Seiberlich, N [1 ]
Heidemann, RM [1 ]
Griswold, MA [1 ]
Jakob, PM [1 ]
机构
[1] Univ Wurzburg, Dept Expt Phys 5, Wurzburg, Germany
关键词
volumetric parallel imaging; controlled aliasing; CAIPIRINHA; SENSE; GRAPPA;
D O I
10.1002/mrm.20787
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The CAIPIRINHA (Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration) concept in parallel imaging has recently been introduced, which modifies the appearance of aliasing artifacts during data acquisition in order to improve the subsequent parallel imaging reconstruction procedure. This concept has been successfully applied to simultaneous multi-slice imaging (MS CAIPIRINHA). In this work, we demonstrate that the concept of CAIPIRINHA can also be transferred to 3D imaging, where data reduction can be performed in two spatial dimensions simultaneously. In MS CAIPIRINHA, aliasing is controlled by providing individual slices with different phase cycles by means of alternating multi-band radio frequency (RF) pulses. In contrast to MS CAIPIRINHA, 2D CAIPIRINHA does not require special RF pulses. Instead, aliasing in 2D parallel imaging can be controlled by modifying the phase encoding sampling strategy. This is done by shifting sampling positions from their normal positions in the undersampled 2D phase encoding scheme. Using this modified sampling strategy, coil sensitivity variations can be exploited more efficiently in multiple dimensions, resulting in a more robust parallel imaging reconstruction.
引用
收藏
页码:549 / 556
页数:8
相关论文
共 21 条
[1]  
BREUER F, 2003, P 20 ANN M ESMRMB RO, P40
[2]  
Breuer F, 2004, P 12 ANN M ISMRM KYO, P326
[3]   Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging [J].
Breuer, FA ;
Blaimer, M ;
Heidemann, RM ;
Mueller, MF ;
Griswold, MA ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :684-691
[4]  
Breuer FA, 2005, P 13 ANN M ISMRM MIA, P2668
[5]  
BREUER FA, 2005, P 13 ANN M ISMRM MIA, P2665
[6]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[7]  
Griswold MA, 2000, MAGN RESON MED, V44, P602, DOI 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO
[8]  
2-5
[9]   VD-AUTO-SMASH imaging [J].
Heidemann, RM ;
Griswold, MA ;
Haase, A ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :1066-1074
[10]  
Jakob PM, 1998, MAGN RESON MATER PHY, V7, P42