Internally stabilized spine: Optimal choice of frequency-encoding gradient direction during MR imaging minimizes susceptibility artifact from titanium vertebral body screws

被引:29
作者
Frazzini, VI
Kagetsu, NJ
Johnson, CE
Destian, S
机构
[1] Department of Radiology, St. Luke's-Roosevelt Hospital Center, Columbia Univ. Coll. Phys. Surgs., New York, NY 10025
关键词
magnetic resonance (MR); artifact; comparative studies; technology; spine; MR; surgery;
D O I
10.1148/radiology.204.1.9205258
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In 18 vertebral bodies with titanium fixation screws and in a phantom model, visualization of the vertebral body marrow was improved and susceptibility artifact was reduced on T1-weighted spin-echo magnetic resonance images when the direction of the frequency-encoding gradient was parallel to the long axis of the screw. A perpendicular direction improved image quality only when the region of interest was adjacent to the tip of the screw. In the phantom, the length of the screw was statistically significantly increased and the width and area were reduced (P <.001) when the gradient was parallel to the long axis of the screw.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 10 条
  • [1] CZERVIONKE LF, 1988, AM J NEURORADIOL, V9, P1149
  • [2] EFFECT OF FIELD-STRENGTH ON SUSCEPTIBILITY ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING
    FARAHANI, K
    SINHA, U
    SINHA, S
    CHIU, LCL
    LUFKIN, RB
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1990, 14 (06) : 409 - 413
  • [3] JOSEPH PM, 1991, MAGNETIC RESONANCE I, P111
  • [4] Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation
    Lewin, JS
    Duerk, JL
    Jain, VR
    Petersilge, CA
    Chao, CP
    Haaga, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) : 1337 - 1345
  • [5] Ludeke K M, 1985, Magn Reson Imaging, V3, P329, DOI 10.1016/0730-725X(85)90397-2
  • [6] MR-GUIDED ASPIRATION BIOPSY - NEEDLE DESIGN AND CLINICAL-TRIALS
    MUELLER, PR
    STARK, DD
    SIMEONE, JF
    SAINI, S
    BUTCH, RJ
    EDELMAN, RR
    WITTENBERG, J
    FERRUCCI, JT
    [J]. RADIOLOGY, 1986, 161 (03) : 605 - 609
  • [7] OEHLER MC, 1995, AM J NEURORADIOL, V16, P1135
  • [8] SAKURAI K, 1992, AM J NEURORADIOL, V13, P1301
  • [9] METALLIC ARTIFACTS ON MR-IMAGES OF THE POSTOPERATIVE SPINE - REDUCTION WITH FAST SPIN-ECHO TECHNIQUES
    TARTAGLINO, LM
    FLANDERS, AE
    VINITSKI, S
    FRIEDMAN, DP
    [J]. RADIOLOGY, 1994, 190 (02) : 565 - 569
  • [10] CONVENTIONAL AND FAST SPIN-ECHO MR-IMAGING - MINIMIZING ECHO TIME
    VINITSKI, S
    MITCHELL, DG
    EINSTEIN, SG
    RAO, VM
    FLANDERS, AE
    SCHWEITZER, ME
    LISTERUD, J
    SCHNALL, MD
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (03): : 501 - 507