Extracellular detection of active membrane currents in the neuron-electrode interface

被引:16
作者
Buitenweg, JR
Rutten, WLC
Marani, E
Polman, SKL
Ursum, J
机构
[1] Univ Twente, Inst Biomed Technol, Signals & Syst Grp, Fac Elect Engn, NL-7500 AE Enschede, Netherlands
[2] Leiden Univ, Med Ctr, Dept Neurosurg, Neuroregulat Grp, Leiden, Netherlands
关键词
neuron-electrode contact; extracellular stimulation; impedance spectroscopy; sealing resistance; cultured neurons; microelectrode arrays;
D O I
10.1016/S0165-0270(02)00021-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although measurement of sealing resistance is an important tool in the assessment of the electrical contacts between cultured cells and substrate embedded micro electrodes, it does not offer information about the type of cell, i.e. neuron or non-neuronal cell. Also, rules for translation of a measured sealing resistance into parameters for successful stimulation, i.e. eliciting an action potential, are not available yet. Therefore, a method is proposed for the detection of active membrane currents, elicited by extracellular current stimulation. The method is based on the prediction of the linear part of the response to an applied stimulus current pulse using an impedance model of the neuron-electrode contact. Active membrane currents are detected in the nonlinear response. which is obtained by subtraction of the predicted linear response from the measured response. The required impedance model parameters are extracted from impedance spectroscopy or directly from the measured responses. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:211 / 221
页数:11
相关论文
共 22 条
[1]   INTERFACING CULTURED NEURONS TO PLANAR SUBSTRATE MICROELECTRODES - CHARACTERIZATION OF THE NEURON-TO-MICROELECTRODE JUNCTION [J].
BOVE, M ;
GRATTAROLA, M ;
MARTINOIA, S ;
VERRESCHI, G .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1995, 38 (02) :255-265
[2]   ADVANTAGES OF USING MICROFABRICATED EXTRACELLULAR ELECTRODES FOR IN-VITRO NEURONAL RECORDING [J].
BRECKENRIDGE, LJ ;
WILSON, RJA ;
CONNOLLY, P ;
CURTIS, ASG ;
DOW, JAT ;
BLACKSHAW, SE ;
WILKINSON, CDW .
JOURNAL OF NEUROSCIENCE RESEARCH, 1995, 42 (02) :266-276
[3]   Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy [J].
Buitenweg, JR ;
Rutten, WLC ;
Willems, WPA ;
van Nieuwkasteele, JW .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (05) :630-637
[4]   Experimental analysis of neuronal dynamics in cultured cortical networks and transitions between different patterns of activity [J].
Canepari, M ;
Bove, M ;
Maeda, E ;
Cappello, M ;
Kawana, A .
BIOLOGICAL CYBERNETICS, 1997, 77 (02) :153-162
[5]  
DEBOER RW, 1978, MED BIOL ENG COMPUT, V16, P1, DOI 10.1007/BF02442925
[6]   SILICON-NEURON JUNCTION - CAPACITIVE STIMULATION OF AN INDIVIDUAL NEURON ON A SILICON CHIP [J].
FROMHERZ, P ;
STETT, A .
PHYSICAL REVIEW LETTERS, 1995, 75 (08) :1670-1673
[7]   MODELING THE NEURON-MICROTRANSDUCER JUNCTION - FROM EXTRACELLULAR TO PATCH RECORDING [J].
GRATTAROLA, M ;
MARTINOIA, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (01) :35-41
[8]   SIMULTANEOUS SINGLE UNIT RECORDING INVITRO WITH A PHOTOETCHED LASER DEINSULATED GOLD MULTI-MICRO-ELECTRODE SURFACE [J].
GROSS, GW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (05) :273-279
[9]   STIMULATION OF MONOLAYER NETWORKS IN CULTURE THROUGH THIN-FILM INDIUM-TIN OXIDE RECORDING ELECTRODES [J].
GROSS, GW ;
RHOADES, BK ;
REUST, DL ;
SCHWALM, FU .
JOURNAL OF NEUROSCIENCE METHODS, 1993, 50 (02) :131-143
[10]   The dynamics of a neuronal culture of dissociated cortical neurons of neonatal rats [J].
Jimbo, Y ;
Kawana, A ;
Parodi, P ;
Torre, V .
BIOLOGICAL CYBERNETICS, 2000, 83 (01) :1-20