A tissue oxygenation monitor using NIR spatially resolved spectroscopy

被引:407
作者
Suzuki, S [1 ]
Takasaki, S [1 ]
Ozaki, T [1 ]
Kobayashi, Y [1 ]
机构
[1] Hamamatsu Photon KK, Syst Div, Hamamatsu, Shizuoka 4313196, Japan
来源
OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF | 1999年 / 3597卷
关键词
spatially resolved spectroscopy; tissue oxygenation index;
D O I
10.1117/12.356862
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new clinical tissue oxygenation monitor, the NIRO-300, has been developed. In addition to monitoring changes in hemoglobin concentration and redox state of cytochrome oxidase, the instrument can measure a Tissue Oxygenation Index (TOI), which is the ratio of oxygenated to total tissue hemoglobin, by utilizing NIR spatially resolved spectroscopy (SRS). In SRS, the slope of light attenuation versus distance is measured at a distant point from the light input, from which the TOI is calculated using photon diffusion theory. Four laser diodes are used as the light source and Class 1 laser light (IEC 825) is irradiated onto the skin. A high gain and low noise amplifier is used in the detector, which enables a large emitter-detector separations of around 5cm. To evaluate the TOI measured by the NIRO-300, it was compared to the data from a blood gas analyzer (SO, value) in measurements made on phantoms containing intralipid and blood. We also made simultaneous measurements by the NIRO-300 and an NIRS machine based on time resolved spectroscopy (TRS) on human arms. In the both measurements, TOI showed an excellent correlation with the data from brood gas analyzer and the TRS machine, which suggests the efficacy of the TOI data also in clinical use.
引用
收藏
页码:582 / 592
页数:11
相关论文
共 12 条
[1]   SYSTEM FOR LONG-TERM MEASUREMENT OF CEREBRAL BLOOD AND TISSUE OXYGENATION ON NEWBORN-INFANTS BY NEAR-INFRARED TRANS-ILLUMINATION [J].
COPE, M ;
DELPY, DT .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (03) :289-294
[2]   ESTIMATION OF OPTICAL PATHLENGTH THROUGH TISSUE FROM DIRECT TIME OF FLIGHT MEASUREMENT [J].
DELPY, DT ;
COPE, M ;
VANDERZEE, P ;
ARRIDGE, S ;
WRAY, S ;
WYATT, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (12) :1433-1442
[3]  
DUNCAN A, 1993, P SOC PHOTO-OPT INS, V1888, P248, DOI 10.1117/12.154641
[4]  
DUPLESSIS AJ, 1995, ANN NEUROL, V37, P488
[5]   NONINVASIVE, INFRARED MONITORING OF CEREBRAL AND MYOCARDIAL OXYGEN SUFFICIENCY AND CIRCULATORY PARAMETERS [J].
JOBSIS, FF .
SCIENCE, 1977, 198 (4323) :1264-1267
[6]   In vivo measurements of the wavelength dependence of tissue-scattering coefficients between 760 and 900 nm measured with time-resolved spectroscopy [J].
Matcher, SJ ;
Cope, M ;
Delpy, DT .
APPLIED OPTICS, 1997, 36 (01) :386-396
[7]   PERFORMANCE COMPARISON OF SEVERAL PUBLISHED TISSUE NEAR-INFRARED SPECTROSCOPY ALGORITHMS [J].
MATCHER, SJ ;
ELWELL, CE ;
COOPER, CE ;
COPE, M ;
DELPY, DT .
ANALYTICAL BIOCHEMISTRY, 1995, 227 (01) :54-68
[8]  
MATCHER SJ, 1993, P SOC PHOTO-OPT INS, V289, P486
[9]  
Miwa M, 1995, P SOC PHOTO-OPT INS, V2389, P142
[10]   POSTOPERATIVE NEUROPSYCHOLOGICAL DYSFUNCTION AND CEREBRAL OXYGENATION DURING CARDIAC-SURGERY [J].
NOLLERT, G ;
MOHNLE, P ;
TASSANIPRELL, P ;
UTTNER, I ;
BORASIO, GD ;
SCHMOECKEL, M ;
REICHART, B .
THORACIC AND CARDIOVASCULAR SURGEON, 1995, 43 (05) :260-264