Removal of pentachlorophenol from wastewater by combined anaerobic-aerobic treatment

被引:13
作者
Bhattacharya, SK
Yuan, Q
Jin, PK
机构
[1] Dept. of Civ. and Environ. Eng., 206 Civil Engineering Building, Tulane University, New Orleans
关键词
acclimation; acetate; activated sludge; aerobic; anaerobic; pentachlorophenol;
D O I
10.1016/0304-3894(96)01751-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this research, the feasibility of combined anaerobic-aerobic biotreatment of pentachlorophenol (PCP) was studied. PCP at 15 mg l(-1) caused inhibition to both batch and continuous anaerobic systems. However, the recovery time was reduced significantly with higher biomass. With proper acclimation, an acetate-fed anaerobic column could degrade 93% of PCP with influent concentration of 15 mg l(-1). With an aerobic process (a conventional activated sludge system) alone, only 74% of 7.5 mg l(-1) of PCP was removed. Using an activated sludge system as a polishing unit following the upflow anaerobic column up to 97% of 15 mg l(-1) of PCP was removed.
引用
收藏
页码:143 / 154
页数:12
相关论文
共 18 条
[1]  
APAJALAHTI JHA, 1986, APPL MICROBIOL BIOT, V25, P62
[2]   PENTACHLOROPHENOL DEGRADATION - A PURE BACTERIAL CULTURE AND AN EPILITHIC MICROBIAL CONSORTIUM [J].
BROWN, EJ ;
PIGNATELLO, JJ ;
MARTINSON, MM ;
CRAWFORD, RL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1986, 52 (01) :92-97
[3]  
CIRELLI DP, PENTACHLOROPHENOL CH, P13
[4]   IUPAC REPORTS ON PESTICIDES .14. ENVIRONMENTAL CHEMISTRY OF PENTACHLOROPHENOL [J].
CROSBY, DG .
PURE AND APPLIED CHEMISTRY, 1981, 53 (05) :1051-1080
[5]   ATTENUATION AND BIODEGRADATION OF CHLOROPHENOLS IN-GROUND WATER AT A FORMER WOOD TREATING FACILITY [J].
DAVIS, A ;
CAMPBELL, J ;
GILBERT, C ;
RUBY, MV ;
BENNETT, M ;
TOBIN, S .
GROUND WATER, 1994, 32 (02) :248-257
[6]  
Eckenfelder W., 1989, IND WATER POLLUTION
[7]  
GEORLITZ DF, 1985, ENVIRON SCI TECHNOL, V19, P955
[8]  
GODSY EW, 1990, EPA S BIOR HAZ WAST, P31
[9]  
Greenberg A. E., 1992, STANDARD METHODS EXA
[10]  
JENKINS SR, 1983, J WATER POLLUT CON F, V55, P448