Constructed wetlands combined with UV disinfection systems for removal of enteric pathogens and wastewater contaminants

被引:26
作者
Azaizeh, H. [1 ,2 ]
Linden, K. G. [3 ]
Barstow, C. [3 ]
Kalbouneh, S. [4 ]
Tellawi, A. [5 ]
Albalawneh, A. [5 ]
Gerchman, Y. [6 ]
机构
[1] Univ Haifa, Inst Appl Res, Galilee Soc, IL-20200 Shefa Amr, Israel
[2] Tel Hai Coll, IL-12208 Upper Galilee, Israel
[3] Univ Colorado, Boulder, CO 80309 USA
[4] BERC, Til, Nablus, Israel
[5] Ctr Agr Reform & Rural Dev Near E CARDNE, Amman 11185, Jordan
[6] Univ Haifa, IL-36006 Tivon, Israel
关键词
COD removal; constructed wetlands; pathogen removal; small communities; UV disinfection; wetland plants; COLONY-FORMING UNIT; BACTERIA; EFFLUENTS;
D O I
10.2166/wst.2012.615
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water shortage is an ongoing cardinal issue in the Middle East region. Wastewater reuse offers some remediation, but to-date many rural communities in the Palestinian Authority (PA) and in Jordan are not connected to centralized wastewater treatment plants (WWTPs), many of them are disposing of their wastewater using infiltration septic tanks. This highlights the need for a small, local, low cost WWTP that can directly benefit local communities, producing effluents suitable for unrestricted irrigation. Constructed wetlands (CWs) could offer a solution as they are relatively easy and cheap to construct and maintain, and effective in removal of many pollutants. Nevertheless, pathogen removal in CWs is often not adequate, calling for additional disinfection. Here we describe the use of low-cost, consumer level, UV based disinfection systems coupled to CWs for wastewater treatment in three CWs: in Israel, Jordan and in the PA. Once mature, our adapted CWs reduced chemical oxygen demand (COD) load, and, given proper use of the UV systems, inactivated indicator bacteria (faecal and E. coli) to levels suitable for irrigation, even when UV transmission (UVT) levels were low (similar to 40%). Our results demonstrate the promise in this combined treatment technique for cheap and simple wastewater treatment suitable for the Middle East region.
引用
收藏
页码:651 / 657
页数:7
相关论文
共 26 条
[1]  
[Anonymous], 2005, Standard methods for the examination of water and waste- water
[2]  
Aquastat, FOOD AGR ORG GLOB IN
[3]   Standardization of methods for fluence (UV dose) determination in bench-scale UV experiments [J].
Bolton, JR ;
Linden, KG .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2003, 129 (03) :209-215
[4]   Evaluation of the relationship between two different methods for enumeration fecal indicator bacteria: Colony-forming unit and most probable number [J].
Cho, Kyung Hwa ;
Han, Dukki ;
Park, Yongeun ;
Lee, Seung Won ;
Cha, Sung Min ;
Kang, Joo-Hyon ;
Kim, Joon Ha .
JOURNAL OF ENVIRONMENTAL SCIENCES, 2010, 22 (06) :846-850
[5]   Giardia and Cryptosporidium removal from waste-water by a duckweed (Lemna gibba L.) covered pond [J].
Falabi, JA ;
Gerba, CP ;
Karpiscak, MM .
LETTERS IN APPLIED MICROBIOLOGY, 2002, 34 (05) :384-387
[6]   Removal of bacteria in subsurface flow wetlands [J].
Green, MB ;
Griffin, P ;
Seabridge, JK ;
Dhobie, D .
WATER SCIENCE AND TECHNOLOGY, 1997, 35 (05) :109-116
[7]   Modeling the relationship between most probable number (MPN) and colony-forming unit (CFU) estimates of fecal coliform concentration [J].
GroneWold, Andrew D. ;
Wolpert, Robert L. .
WATER RESEARCH, 2008, 42 (13) :3327-3334
[8]  
Gvirtzman Haim, 2010, EKOLOGIA VSVIVA, V2, P46
[9]  
Kadlec R.H., 2000, 8 IWA
[10]   Multi-species plant systems for wastewater quality improvements and habitat enhancement [J].
Karpiscak, MM ;
Gerba, CP ;
Watt, PM ;
Foster, KE ;
Falabi, JA .
WATER SCIENCE AND TECHNOLOGY, 1996, 33 (10-11) :231-236