A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis

被引:170
作者
Glass, Dianne H. [1 ]
Roberts, Cynthia J. [1 ,2 ]
Litsky, Alan S. [1 ,3 ]
Weber, Paul A. [2 ]
机构
[1] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Ophthalmol, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Orthopaed, Columbus, OH 43210 USA
关键词
D O I
10.1167/iovs.07-1321
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE. To develop a method for evaluating viscosity and elasticity of the cornea and to examine the effect that both properties have on hysteresis. METHODS. A three-component spring and dashpot model was created in Simulink in Matlab to represent the purely elastic and viscoelastic behavior of the cornea during a measurement using device called an ocular response analyzer (ORA). Values for elasticity and viscosity were varied while sinusoidal stress was applied to the model. The simulated stresses were used to determine how hysteresis is affected by the individual components of elasticity, viscosity, and maximum stress. To validate the model, high-speed photography was used to measure induced strain in a corneal phantom during ORA measurement. This measured strain was compared with the strains simulated by the model. RESULTS. When the spring in the viscoelastic portion of the model was stiffened, hysteresis decreased. When the spring in the purely elastic element was stiffened, hysteresis increased. If both springs were stiffened together, hysteresis peaked strongly as a function of the viscosity of the viscoelastic element. Below the peak value, lower elasticity was associated with higher hysteresis. Above the peak value, higher elasticity was associated with higher hysteresis. In addition, hysteresis increased as the air maximum pressure was increased. Measurements from phantom corresponded to predictions from the model. CONCLUSIONS. A viscoelastic model is presented to illustrate how changing viscosity and elasticity may affect hysteresis. Low hysteresis can be associated with either high elasticity or low elasticity, depending on the viscosity, a finding consistent with clinical reports.
引用
收藏
页码:3919 / 3926
页数:8
相关论文
共 31 条
[1]
BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS [J].
ANDREASSEN, TT ;
SIMONSEN, AH ;
OXLUND, H .
EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) :435-441
[2]
Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[3]
Influence of corneal variables on accuracy of intraocular pressure measurement [J].
Damji, KF ;
Muni, RH ;
Munger, RM .
JOURNAL OF GLAUCOMA, 2003, 12 (01) :69-80
[4]
An analytically solvable model for biomechanical response of the cornea to refractive surgery [J].
Djotyan, GP ;
Kurtz, RM ;
Fernández, DC ;
Juhasz, T .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05) :440-445
[5]
Viscoelastic material properties of the peripapillary sclera in normal and early-glaucoma monkey eyes [J].
Downs, JC ;
Suh, JKF ;
Thomas, KA ;
Bellezza, AJ ;
Hart, RT ;
Burgoyne, CF .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (02) :540-546
[6]
Hysteresis: New mechanospeak for the ophthalmologist [J].
Dupps, William J., Jr. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (09) :1499-1501
[7]
EDMUND C, 1988, ACTA OPHTHALMOL, V66, P134
[8]
Edmund C, 1989, Acta Ophthalmol Suppl, V193, P1
[9]
EDMUND C, 1987, ACTA OPHTHALMOL, V65, P545
[10]
Assessment of corneal biomechanical properties and their variation with age [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Brown, Michael ;
Rama, Paolo ;
Campanelli, Marino ;
Pye, David .
CURRENT EYE RESEARCH, 2007, 32 (01) :11-19