A microfluidic platform with digital readout and ultra-low detection limit for quantitative point-of-care diagnostics

被引:44
作者
Li, Ying [1 ]
Xuan, Jie [2 ]
Song, Yujun [1 ,3 ]
Wang, Ping [2 ]
Qin, Lidong [1 ,3 ]
机构
[1] Houston Methodist Res Inst, Dept Nanomed, Houston, TX 77030 USA
[2] Houston Methodist Hosp, Dept Pathol & Genom Med, Houston, TX 77030 USA
[3] Cornell Univ, Weill Med Coll, Dept Cell & Dev Biol, New York, NY 10065 USA
关键词
BAR-CHART CHIP; HEART-FAILURE; EMERGENCY-DEPARTMENT; NATRIURETIC-PEPTIDE; BIOMARKERS; CANCER; BNP; DISEASE; DEVICES; MARKERS;
D O I
10.1039/c5lc00529a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitative assays are of great importance for point-of-care (POC) diagnostics because they can offer accurate information on the analytes. However, current POC devices often require an accessory instrument to give quantitative readouts for protein biomarkers, especially for those at very low concentration levels. Here, we report a microfluidic platform, the digital volumetric bar-chart chip (DV-chip), for quantitative POC diagnostics with ultra-low detection limits that are readable with the naked eye. Requiring no calibration, the DV-chip presents a digital ink bar chart (representing multiple bits composed of 0 and 1) for the target biomarker based on direct competition between O-2 generated by the experimental and control samples. The bar chart clearly and accurately defines target concentration, allowing identification of disease status. For the standard PtNP solutions, the detection limit of the platform is approximately 0.1 pM and the dynamic range covers four orders of magnitude from 0.1 to 1000 pM. CEA samples with concentrations of 1 ng mL(-1) and 1.5 ng mL(-1) could be differentiated by the device. We also performed the ELISA assay for B-type natriuretic peptide (BNP) in 20 plasma samples from heart failure patients and the obtained on-chip data were in agreement with the clinical results. In addition, BNP was detectable at concentrations of less than 5 pM, which is three orders of magnitude lower than the detection limit of the previously reported readerless digital methods. By the integration of gas competition, volumetric bar chart, and digital readout, the DV-chip possesses merits of portability, visible readout, and ultra-low detection limit, which should offer a powerful platform for quantitative POC diagnostics in clinical settings and personalized detection.
引用
收藏
页码:3300 / 3306
页数:7
相关论文
共 40 条
[1]   Novel biomarkers in chronic heart failure [J].
Ahmad, Tariq ;
Fiuzat, Mona ;
Felker, G. Michael ;
O'Connor, Christopher .
NATURE REVIEWS CARDIOLOGY, 2012, 9 (06) :347-359
[2]   Point-of-care and point-of-procedure optical imaging technologies for primary care and global health [J].
Boppart, Stephen A. ;
Richards-Kortum, Rebecca .
SCIENCE TRANSLATIONAL MEDICINE, 2014, 6 (253)
[3]   Evidence-Based Point-of-Care Diagnostics: Current Status and Emerging Technologies [J].
Chan, Cangel Pui Yee ;
Mak, Wing Cheung ;
Cheung, Kwan Yee ;
Sin, King Keung ;
Yu, Cheuk Man ;
Rainer, Timothy H. ;
Renneberg, Reinhard .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 6, 2013, 6 :191-211
[4]   Early detection of ovarian cancer [J].
Das, Partha M. ;
Bast, Robert C., Jr. .
BIOMARKERS IN MEDICINE, 2008, 2 (03) :291-303
[5]  
de la Rica R, 2012, NAT NANOTECHNOL, V7, P821, DOI [10.1038/nnano.2012.186, 10.1038/NNANO.2012.186]
[6]   ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2008 [J].
Dickstein, Kenneth ;
Cohen-Solal, Alain ;
Filippatos, Gerasimos ;
McMurray, John J. V. ;
Ponikowski, Piotr ;
Poole-Wilson, Philip Alexander ;
Stromberg, Anna ;
van Veldhuisen, Dirk J. ;
Atar, Dan ;
Hoes, Arno W. ;
Keren, Andre ;
Mebazaa, Alexandre ;
Nieminen, Markku ;
Priori, Silvia Giuliana ;
Swedberg, Karl .
EUROPEAN HEART JOURNAL, 2008, 29 (19) :2388-2442
[7]   SlipChip [J].
Du, Wenbin ;
Li, Liang ;
Nichols, Kevin P. ;
Ismagilov, Rustem F. .
LAB ON A CHIP, 2009, 9 (16) :2286-2292
[8]   Serum tumor markers in breast cancer: Are they of clinical value? [J].
Duffy, MJ .
CLINICAL CHEMISTRY, 2006, 52 (03) :345-351
[9]  
Eroglu S, 2008, BIOCHEM MEDICA, V18, P183
[10]  
Fakih MG, 2006, ONCOLOGY-NY, V20, P579