Comparison of deconvolution techniques using a distribution mixture parameter estimation: Application in single photon emission computed tomography imagery

被引:16
作者
Mignotte, M
Meunier, J
Soucy, JP
Janicki, C
机构
[1] Univ Montreal, Dept Informat & Rech Operat, DIRO, Montreal, PQ H3C 3J7, Canada
[2] Inst Natl Rech Informat & Automat, F-78153 Le Chesnay, France
[3] Ottawa Hosp, Ottawa, ON K1Y 4E9, Canada
[4] Univ Montreal, Notre Dame Hosp, CHUM, Montreal, PQ H2L 4M1, Canada
关键词
D O I
10.1117/1.1426082
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Thanks to its ability to yield functionally rather than anatomically-based information, the single photon emission computed tomography (SPECT) imagery technique has become a great help in the diagnostic of cerebrovascular diseases which are the third most common cause of death in the USA and Europe, Nevertheless, SPECT images are very blurred and consequently their interpretation is difficult. In order to improve the spatial resolution of these images and then to facilitate their interpretation by the clinician, we propose to implement and to compare the effectiveness of different existing "blind" or "supervised" deconvolution methods. To this end, we present an accurate distribution mixture parameter estimation procedure which takes into account the diversity of the laws in the distribution mixture of a SPECT image. In our application, parameters of this distribution mixture are efficiently exploited in order to prevent overfitting of the noisy data for the iterative deconvolution techniques without regularization term, or to determine the exact support of the object to be restored when this one is needed. Recent blind deconvolution techniques such as the NAS-RIF algorithm, [D. Kundur and D. Hatzinakos, "Blind image restoration via recursive filtering using deterministic constraints," in Proc. International Conf. On Acoustics, Speech, and Signal Processing, Vol. 4, pp. 547-549 (1996).] combined with this estimation procedure, can be efficiently applied in SPECT imagery and yield promising results. (C) 2002 SPIE and IST.
引用
收藏
页码:11 / 24
页数:14
相关论文
共 23 条
[1]  
[Anonymous], 1991, BRAIN BLOOD FLOW NEU
[2]  
[Anonymous], 1990, Signal Processing, Image Processing and Patten Recognition
[3]   ITERATIVE BLIND DECONVOLUTION METHOD AND ITS APPLICATIONS [J].
AYERS, GR ;
DAINTY, JC .
OPTICS LETTERS, 1988, 13 (07) :547-549
[4]  
BESAG J, 1986, J R STAT SOC B, V48, P259
[5]  
BIGGS DSC, 1998, P SOC PHOTO-OPT INS, V3461, P33
[6]   PRERECONSTRUCTION RESTORATION OF MYOCARDIAL SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IMAGES [J].
BOULFELFEL, D ;
RANGAYYAN, RM ;
HAHN, LJ ;
KLOIBER, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :336-341
[7]  
BRAATHEN B, 1993, MACHINE GRAPHICS VIS, V2, P39
[8]  
CURRY TS, 1990, CHRISTENSENS PHYSICS
[9]  
DEMPSTER AP, 1976, J ROY STAT SOC B MET, V39, P1
[10]   Spatial registration and normalization of images [J].
Friston, KJ ;
Ashburner, J ;
Frith, CD ;
Poline, JB ;
Heather, JD ;
Frackowiak, RSJ .
HUMAN BRAIN MAPPING, 1995, 3 (03) :165-189