A microwave powered thermospray nebulizer for liquid sample introduction in inductively coupled plasma atomic emission spectrometry

被引:24
作者
Bordera, L [1 ]
Todoli, JL [1 ]
Mora, J [1 ]
Canals, A [1 ]
Hernandis, V [1 ]
机构
[1] UNIV ALICANTE, DEPT QUIM ANALIT, E-03071 ALICANTE, SPAIN
关键词
D O I
10.1021/ac961247a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new thermospray nebulizer based on the absorption of microwave radiation (MWTN) by aqueous solutions of strong acids is presented for the first time, To this end, a given length of the sample capillary is placed inside the cavity of a focused microwave system. A small piece of a narrower capillary tubing is connected at the tip of the sample capillary, outside the microwave cavity, to build up pressure, Drop size distributions of primary aerosols are exhaustively measured in order to evaluate the influence of several experimental variables (microwave power, liquid now, irradiation length, inner diameter of the outlet capillary, nature and concentration of the acid) on the characteristics of the primary aerosol that are related to the emission signal. These experiments have been performed mainly to increase our understanding of the microscopic process of this new type of aerosol generation. A standard Meinhard nebulizer was employed for comparison, Under the best conditions the entire aerosol volume is contained in droplets smaller than 20 mu m compared with 45% of the volume of the aerosol generated by the Meinhard, Hence, higher analyte and aerosol transport rates are to be expected for the MWTN compared with the Meinhard nebulizer. As any highly efficient nebulizer, MWTN requires a desolvation unit, For solutions 0.75 M in strong acid, the new nebulizer improves sensitivity (1.0-2.8 times), limits of detection (1.2-3.0 times), and background equivalent concentration (0.9-2.0 times) as compared to the standard Meinhard nebulizer, features many of the advantages of the conventional thermospray nebulizer, and overcomes some of its drawbacks (MWTN does not show corrosion problems and works at lower pressure, the aerosol characteristics are not modified when the PTFE capillary is replaced).
引用
收藏
页码:3578 / 3586
页数:9
相关论文
共 33 条
[1]   WET ASHING OF SOME BIOLOGICAL SAMPLES IN A MICROWAVE OVEN [J].
ABUSAMRA, A ;
MORRIS, JS ;
KOIRTYOHANN, SR .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1475-1477
[2]  
[Anonymous], MALVERN INSTRUMENTS
[3]  
Bordera L, 1996, FRESEN J ANAL CHEM, V355, P112
[4]  
BORDERA L, 1996, J AEROSOL SCI, V27, pS387
[5]   INTERFACING WITH AEROSOLS - CONCEPT, PLACE, AND TIME [J].
BROWNER, RF .
MICROCHEMICAL JOURNAL, 1989, 40 (01) :4-29
[6]   EFFECT OF ANALYTE AND SOLVENT TRANSPORT ON SIGNAL INTENSITIES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
BROWNER, RF ;
CANALS, A ;
HERNANDIS, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (05) :659-673
[7]   EVOLUTION OF DROP SIZE DISTRIBUTIONS FOR PNEUMATICALLY GENERATED AEROSOLS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CANALS, A ;
HERNANDIS, V ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (06) :591-601
[8]   EMPIRICAL-MODEL FOR ESTIMATING DROP SIZE DISTRIBUTIONS OF AEROSOLS GENERATED BY INDUCTIVELY COUPLED PLASMA NEBULIZERS [J].
CANALS, A ;
WAGNER, J ;
BROWNER, RF ;
HERNANDIS, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (9-11) :1321-1335
[9]   EXPERIMENTAL EVALUATION OF THE NUKIYAMA-TANASAWA EQUATION FOR PNEUMATIC NEBULIZERS USED IN PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CANALS, A ;
HERNANDIS, V ;
BROWNER, RF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (01) :61-66
[10]   FUNDAMENTAL-STUDIES ON PNEUMATIC GENERATION AND AEROSOL TRANSPORT IN ATOMIC SPECTROMETRY - EFFECT OF MINERAL ACIDS ON EMISSION INTENSITY IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
CANALS, A ;
HERNANDIS, V ;
TODOLI, JL ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :305-321