A liquid chromatographic-tandem mass spectrometric method for determination of artesunate and its metabolite dihydroartemisinin in human plasma

被引:64
作者
Hanpithakpong, W. [1 ]
Kamanikom, B. [1 ]
Dondorp, A. M. [1 ,2 ]
Singhasivanon, P. [1 ]
White, N. J. [1 ,2 ]
Day, N. P. J. [1 ,2 ]
Lindegardh, N. [1 ,2 ]
机构
[1] Mahidol Univ, Fac Trop Med, Bangkok 10400, Thailand
[2] Univ Oxford, Nuffield Dept Clin Med, Ctr Trop Med, Oxford, England
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 876卷 / 01期
基金
英国惠康基金;
关键词
Antimalarial; Artesunate; Dihydroartemisinin; High throughput; Liquid chromatography/tandem mass spectrometry (LC-MS/MS); Stable isotope labeled (SIL) internal standard; Solid phase extraction (SPE);
D O I
10.1016/j.jchromb.2008.10.018
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A bioanalytical method for the analysis of artesunate and its metabolite dihydroartemisinin in human plasma using high throughput solid-phase extraction in the 96-wellplate format and liquid chromatography coupled to positive tandem mass spectroscopy has been developed and validated. The method was validated according to published FDA guidelines and showed excellent performance. The within-clay and between-day precisions expressed as RSD, were lower than 7% at all tested concentrations including the lower limit of quantification. Using 50 mu l plasma the calibration range was 1.19-728 ng/ml with a limit of detection at 0.5 ng/ml for artesunate and 1.96-2500 ng/ml with a limit of detection at 0.6 ng/ml for dihydroartemisinin. Using 250 mu l of plasma sample the lower limit of quantification was decreased to 0.119 ng/ml for artesunate and 0.196 ng/ml dihydroartemisinin. Validation of over-curve samples in plasma ensured that accurate estimation Would be possible with dilution if samples went outside the calibration range. The method was free from matrix effects as demonstrated both graphically and quantitatively. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 30 条
[1]
PFMDR1 and in vivo resistance to artesunate-mefloquine in falciparum malaria on the Cambodian-Thai border [J].
Alker, Alisa P. ;
Lim, Pharath ;
Sem, Rithy ;
Shah, Naman K. ;
Yi, Poravuth ;
Bouth, Denis Mey ;
Tsuyuoka, Reiko ;
Maguire, Jason D. ;
Fandeur, Thierry ;
Ariey, Frederic ;
Wongsrichanalai, Chansuda ;
Meshnick, Steven R. .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2007, 76 (04) :641-647
[2]
[Anonymous], 2007, Wkly Epidemiol Rec, V82, P360
[3]
[Anonymous], 2015, Guidelines for the treatment of malaria
[4]
Selective high-performance liquid chromatographic determination of artesunate and alpha- and beta-dihydroartemisinin in patients with falciparum malaria [J].
Batty, KT ;
Davis, TME ;
Thu, LTA ;
Binh, TQ ;
Anh, TK ;
Ilett, KF .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 677 (02) :345-350
[5]
Breman JG, 2004, AM J TROP MED HYG, V71, P1
[6]
Plasmodium falciparum antimalarial drug susceptibility on the north-western border of Thailand during five years of extensive use of artesunate-mefloquine [J].
Brockman, A ;
Price, RN ;
van Vugt, M ;
Heppner, DG ;
Walsh, D ;
Sookto, P ;
Wimonwattrawatee, T ;
Looareesuwan, S ;
White, NJ ;
Nosten, F .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2000, 94 (05) :537-544
[7]
CABRI W, 2008, J CHROMATOGR B
[8]
EDLUND PO, 1984, ACTA PHARM SUEC, V21, P223
[9]
Faiz MA, 2005, LANCET, V366, P717
[10]
Direct analysis of artemisinin in plasma and saliva using coupled-column high-performance liquid chromatography with a restricted-access material pre-column [J].
Gordi, T ;
Nielsen, E ;
Yu, ZX ;
Westerlund, D ;
Ashton, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 742 (01) :155-162