Torque ripple reduction in DTC of induction motor driven by three-level inverter with low switching frequency

被引:178
作者
Lee, KB [1 ]
Song, JH
Choy, I
Yoo, JY
机构
[1] Korea Univ, Dept Elect Engn, Seoul 136701, South Korea
[2] Korea Inst Sci & Technol, Intelligent Syst Control Res Ctr, Seoul 136791, South Korea
关键词
direct torque control; induction motor; three-level inverters; torque ripple reduction;
D O I
10.1109/63.988836
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
A torque ripple reduction technique of direct torque control (DTC) for high power induction motors driven by three-level inverters with the inverter switching frequency limited around 0.5-1 kHz level is presented. It is noted that conventional two-level DTC algorithms to reduce torque ripple are devised for applications with relatively high switching frequency above 2-3 kHz and cannot accomplish satisfactory torque ripple reduction for three-level inverter systems with such lower switching frequencies. A new DTC algorithm, especially for low switching frequency inverter system, illustrates quite reduced torque ripple characteristics all over the operating speed region. Simulation and experimental results show effectiveness of the proposed control algorithm.
引用
收藏
页码:255 / 264
页数:10
相关论文
共 13 条
[1]
ALFONSO D, 1999, P EPE 99 C
[2]
Buja G, 1998, IEEE IND ELEC, pT50, DOI 10.1109/IECON.1998.723933
[3]
BUSSCHOTS F, 1997, P EPE 97 C
[4]
Casadei D, 1997, IEEE IND ELEC, P552, DOI 10.1109/IECON.1997.671793
[5]
CHAPUIS YA, 2000, P IPEC TOK 2000, P1189
[6]
FLACH E, 1999, P EPE 99 C
[7]
Idris NRN, 2000, P APEC 00 C, P154
[8]
New direct torque control of induction motor for minimum torque ripple and constant switching frequency [J].
Kang, JK ;
Sul, SK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (05) :1076-1082
[9]
Lee KB, 2000, IEEE POWER ELECTRON, P448, DOI 10.1109/PESC.2000.878900
[10]
LUO YC, 2000, P IPEC TOK JAP, P1087