Within-day and between-day repeatability of measurements with an electronic nose in patients with COPD

被引:63
作者
Bofan, Maria [1 ]
Mores, Nadia [2 ]
Baron, Marco [1 ]
Dabrowska, Malgorzata [2 ]
Valente, Salvatore [3 ]
Schmid, Maurizio [1 ]
Trove, Andrea [4 ]
Conforto, Silvia [1 ]
Zini, Gina [5 ]
Cattani, Paola [6 ]
Fuso, Leonello [3 ]
Mautone, Antonella [3 ]
Mondino, Chiara [7 ]
Pagliari, Gabriella [3 ]
D'Alessio, Tommaso [1 ]
Montuschi, Paolo [3 ]
机构
[1] Univ Roma 3, Fac Engn, Dept Appl Elect, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Fac Med, Dept Pharmacol, I-00168 Rome, Italy
[3] Univ Cattolica Sacro Cuore, Fac Med, Dept Internal Med & Geriatr, I-00168 Rome, Italy
[4] IDI, San Carlo di Nancy Hosp, Dept Med, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Fac Med, Dept Hematol, I-00168 Rome, Italy
[6] Univ Cattolica Sacro Cuore, Fac Med, Dept Microbiol, I-00168 Rome, Italy
[7] IDI, Dept Immunodermatol, Rome, Italy
关键词
EXHALED NITRIC-OXIDE; VOLATILE ORGANIC-COMPOUNDS; LUNG-CANCER; BREATH CONDENSATE; DIAGNOSIS; DISCRIMINATION; ARRAY; FOOD;
D O I
10.1088/1752-7155/7/1/017103
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Electronic noses (e-noses), artificial sensor systems generally consisting of chemical sensor arrays for the detection of volatile compound profiles, have potential applications in respiratory medicine. We assessed within-day and between-day repeatability of an e-nose made from 32 sensors in patients with stable chronic obstructive pulmonary disease (COPD). We also compared between-day repeatability of an e-nose, fraction of exhaled nitric oxide (FENO) and pulmonary function testing. Within-day and between-day repeatability for the e-nose was assessed in two breath samples collected 30 min and seven days apart, respectively. Repeatability was expressed as an intraclass correlation coefficient (ICC). All sensors had ICC above 0.5, a value that is considered acceptable for repeatability. Regarding within-day repeatability, ICC ranged from 0.75 to 0.84 (mean = 0.80 +/- 0.004). Sensors 6 and 19 were the most reproducible sensors (both, ICC = 0.84). Regarding between-day repeatability, ICC ranged from 0.57 to 0.76 (mean = 0.68 +/- 0.01). Sensor 19 was the most reproducible sensor (ICC = 0.76). Within-day e-nose repeatability was greater than between-day repeatability (P < 0.0001). Between-day repeatability of FENO (ICC = 0.91) and spirometry (ICC range = 0.94-0.98) was greater than that of e-nose (mean ICC = 0.68). In patients with stable COPD, the e-nose used in this study has acceptable within-day and between-day repeatability which varies between different sensors.
引用
收藏
页数:8
相关论文
共 39 条
[1]
[Anonymous], 1999, Am J Respir Crit Care Med, V160, P2104
[2]
[Anonymous], 2011, GLOB STRAT DIAGN MAN
[3]
Electronic Noses and Tongues: Applications for the Food and Pharmaceutical Industries [J].
Baldwin, Elizabeth A. ;
Bai, Jinhe ;
Plotto, Anne ;
Dea, Sharon .
SENSORS, 2011, 11 (05) :4744-4766
[4]
Olfactory systems for medical applications [J].
D'Amico, A. ;
Di Natale, C. ;
Paolesse, R. ;
Macagnano, A. ;
Martinelli, E. ;
Pennazza, G. ;
Santonico, A. ;
Bernabei, M. ;
Roscioni, C. ;
Galluccio, G. ;
Bono, R. ;
Finazzi Agro, E. ;
Rullo, S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (01) :458-465
[5]
An investigation on electronic nose diagnosis of lung cancer [J].
D'Amico, Arnaldo ;
Pennazza, Giorgio ;
Santonico, Marco ;
Martinelli, Eugenio ;
Roscioni, Claudio ;
Galluccio, Giovanni ;
Paolesse, Roberto ;
Di Natale, Corrado .
LUNG CANCER, 2010, 68 (02) :170-176
[6]
Metabonomic analysis of exhaled breath condensate in adults by nuclear magnetic resonance spectroscopy [J].
de Laurentiis, G. ;
Paris, D. ;
Melck, D. ;
Maniscalco, M. ;
Marsico, S. ;
Corso, G. ;
Motta, A. ;
Sofia, M. .
EUROPEAN RESPIRATORY JOURNAL, 2008, 32 (05) :1175-1183
[7]
Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors [J].
Di Natale, C ;
Macagnano, A ;
Martinelli, E ;
Paolesse, R ;
D'Arcangelo, G ;
Roscioni, C ;
Finazzi-Agrò, A ;
D'Amico, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) :1209-1218
[8]
An electronic nose in the discrimination of patients with asthma and controls [J].
Dragonieri, Silvano ;
Schot, Robert ;
Mertens, Bart J. A. ;
Le Cessie, Saskia ;
Gauw, Stefanie A. ;
Spanevello, Antonio ;
Resta, Onofrio ;
Willard, Nico P. ;
Vink, Teunis J. ;
Rabe, Klaus F. ;
Bel, Elisabeth H. ;
Sterk, Peter J. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2007, 120 (04) :856-862
[9]
An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD [J].
Dragonieri, Silvano ;
Annema, Jouke T. ;
Schot, Robert ;
van der Schee, Marc P. C. ;
Spanevello, Antonio ;
Carratu, Pierluigi ;
Resta, Onofrio ;
Rabe, Klaus F. ;
Sterk, Peter J. .
LUNG CANCER, 2009, 64 (02) :166-170
[10]
An Official ATS Clinical Practice Guideline: Interpretation of Exhaled Nitric Oxide Levels (FENO) for Clinical Applications [J].
Dweik, Raed A. ;
Boggs, Peter B. ;
Erzurum, Serpil C. ;
Irvin, Charles G. ;
Leigh, Margaret W. ;
Lundberg, Jon O. ;
Olin, Anna-Carin ;
Plummer, Alan L. ;
Taylor, D. Robin .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 184 (05) :602-615