1/f noise as a diagnostic tool to investigate the quality of anisotropic conductive adhesive (ACA) bonds for ball grid arrays (BGA's)

被引:4
作者
Jongen, RJJM [1 ]
VanDamme, LKJ
Bonné, HH
De Vries, JWC
机构
[1] Eindhoven Univ Technol, Dept Elect Engn, NL-5600 MB Eindhoven, Netherlands
[2] Philips Ctr Ind Technol, EP&A, NL-5600 MD Eindhoven, Netherlands
来源
FLUCTUATION AND NOISE LETTERS | 2003年 / 3卷 / 01期
关键词
anisotropic conductive adhesives; ball grid arrays; reliability; 1/f contact noise; multispot contacts;
D O I
10.1142/S0219477503001075
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
Reliability assessment of conductive adhesive bonds by humidity and temperature tests is time consuming and does not provide enough information about the details of the onset of degradation. There is a need for measurements that can give an early warning about the contact quality with more quantitative details about its degradation. Here 1/f noise of such contact arrays is investigated before and after temperature and humidity stress tests with different durations. 1/f Noise stems from conductance fluctuations. We investigated the constriction resistance 1/f noise S-R of the contact constriction resistance Re before accelerated aging and during aging at temperatures of 85degreesC and 110degreesC with an 85% relative humidity. Noise analysis on non-degraded samples is also a fast diagnostic tool for reliability characterization. From the analysis based on a noise model for a multispot contact, the onset of constriction resistance increase goes hand in hand with a strong increase in resistance noise. This is understood and can be characterized by a reduction in the electrical contact area A(e). The degree of contact degradation is expressed in a reduction of the real electrical contact area A(e) of a multispot contact and is quantitatively given by the D-factor.
引用
收藏
页码:L31 / L50
页数:20
相关论文
共 17 条
[1]   Characterization of anisotropically conductive adhesive interconnections by 1/f noise measurements [J].
Behner, U ;
Haug, R ;
Schutz, R ;
Hartnagel, HL .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART A, 1998, 21 (02) :243-247
[2]  
BEHNER U, 1999, THESIS DARMSTADT U
[3]  
Di Giacomo G., 1997, RELIABILITY ELECT PA
[4]  
GREENWOOD JA, 1966, P 3 INT RES S EL CON, P5
[5]  
Holm R., 1967, Electric Contacts: Theory and Applications, DOI DOI 10.1007/978-3-662-06688-1
[6]   EXPERIMENTAL STUDIES ON 1-F NOISE [J].
HOOGE, FN ;
KLEINPENNING, TGM ;
VANDAMME, LKJ .
REPORTS ON PROGRESS IN PHYSICS, 1981, 44 (05) :479-532
[7]   Current-induced degradation of isotropically conductive adhesives [J].
Kotthaus, S ;
Haug, R ;
Schafer, H ;
Hennemann, OD .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART A, 1998, 21 (02) :259-265
[8]  
Lau JH, 1998, ELECT PACKAGING DESI
[9]   CHARACTERIZATION OF IMPULSE-FRITTING PROCEDURES OF CONTACTS BY MEASURING 1-F NOISE [J].
ORTMANS, LHF ;
VANDAMME, LKJ .
APPLIED PHYSICS, 1976, 9 (02) :147-151
[10]   AC METHOD FOR MEASURING LOW-FREQUENCY RESISTANCE FLUCTUATION SPECTRA [J].
SCOFIELD, JH .