Recommendations for the standardization of light transmission aggregometry: a consensus of the working party from the platelet physiology subcommittee of SSC/ISTH

被引:364
作者
Cattaneo, M. [1 ]
Cerletti, C. [2 ]
Harrison, P. [3 ]
Hayward, C. P. M. [4 ,5 ]
Kenny, D. [6 ]
Nugent, D. [7 ]
Nurden, P. [8 ]
Rao, A. K. [9 ]
Schmaier, A. H. [10 ,11 ]
Watson, S. P. [12 ]
Lussana, F. [1 ]
Pugliano, M. T. [1 ]
Michelson, A. D. [13 ]
机构
[1] Univ Milan, Unita Med 3, Osped San Paolo, Dipartimento Sci Salute, I-20142 Milan, Italy
[2] Univ Cattolica, Lab Ric, Campobasso, Italy
[3] Univ Birmingham, Sch Med, Sch Immun & Infect, Birmingham, W Midlands, England
[4] McMaster Univ, Dept Med, Hamilton, ON, Canada
[5] Hamilton Reg Lab Med Program, Hamilton, ON, Canada
[6] Royal Coll Surgeons Ireland, Dept Mol & Cellular Therapeut, Dublin 2, Ireland
[7] CHOC Childrens Hosp, Orange, CA USA
[8] Hop Xavier Arnozan, Ctr Reference Pathol Plaquettaires Plateforme Tec, Pessac, France
[9] Temple Univ, Sol Sherry Thrombosis Res Ctr, Sch Med, Philadelphia, PA 19122 USA
[10] Case Western Reserve Univ, Dept Med, Cleveland, OH 44106 USA
[11] Univ Hosp Case Med Ctr, Cleveland, OH USA
[12] Univ Birmingham, Ctr Cardiovasc Sci, Inst Biomed Res, Sch Clin & Expt Med,Coll Med & Dent Sci, Birmingham, W Midlands, England
[13] Harvard Univ, Sch Med, Dana Farber Canc Inst, Div Hematol Oncol,Boston Childrens Hosp,Ctr Plate, Boston, MA 02115 USA
关键词
RICH PLASMA; ANTIPLATELET THERAPY; AGGREGATION; DISORDERS; COUNT; VARIABILITY; CLOPIDOGREL; REACTIVITY; STRESS; SYSTEM;
D O I
10.1111/jth.12231
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:1183 / 1189
页数:7
相关论文
共 37 条
[1]  
[Anonymous], 2008, CLIN LAB STANDARDS I
[2]  
[Anonymous], JAMA
[3]   PLATELET-AGGREGATION MONITORED IN A 96-WELL MICROPLATE READER IS USEFUL FOR EVALUATION OF PLATELET AGONISTS AND ANTAGONISTS [J].
BEDNAR, B ;
CONDRA, C ;
GOULD, RJ ;
CONNOLLY, TM .
THROMBOSIS RESEARCH, 1995, 77 (05) :453-463
[4]   AGGREGATION OF BLOOD PLATELETS BY ADENOSINE DIPHOSPHATE AND ITS REVERSAL [J].
BORN, GVR .
NATURE, 1962, 194 (4832) :927-&
[5]   Can platelet aggregometry be standardized? [J].
Breddin, HK .
PLATELETS, 2005, 16 (3-4) :151-158
[6]  
Brook R H, 1986, Int J Technol Assess Health Care, V2, P53
[7]   ELECTRONIC AGGREGOMETER - NOVEL DEVICE FOR ASSESSING PLATELET BEHAVIOR IN BLOOD [J].
CARDINAL, DC ;
FLOWER, RJ .
JOURNAL OF PHARMACOLOGICAL METHODS, 1980, 3 (02) :135-158
[8]   A prospective cohort study of light transmission platelet aggregometry for bleeding disorders: Is testing native platelet-rich plasma non-inferior to testing platelet count adjusted samples? [J].
Castilloux, Jean Francois ;
Moffat, Karen A. ;
Liu, Yang ;
Seecharan, Jodi ;
Pai, Menaka ;
Hayward, Catherine P. M. .
THROMBOSIS AND HAEMOSTASIS, 2011, 106 (04) :675-682
[9]   Results of a worldwide survey on the assessment of platelet function by light transmission aggregometry: a report from the platelet physiology subcommittee of the SSC of the ISTH [J].
Cattaneo, M. ;
Hayward, C. P. M. ;
Moffat, K. A. ;
Pugliano, M. T. ;
Liu, Y. ;
Michelson, A. D. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (06) :1029-1029
[10]   Platelet aggregation studies: autologous platelet-poor plasma inhibits platelet aggregation when added to platelet-rich plasma to normalize platelet count [J].
Cattaneo, Marco ;
Lecchi, Anna ;
Zighetti, Maddalena Loredana ;
Lussana, Federico .
HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2007, 92 (05) :694-697